Angewandte Chemie · 2020 · 35 citations · 33 references
EngineeringBioengineeringBiomedical EngineeringBiomedical ImagingBiosensorsSensorsFluorescence SpectroscopyMedical Imaging InstrumentationMolecular Imaging In OncologyOptical BiosensorsTumor ImagingFluorescent BiosensingFörster Resonance Energy Transfer (Fret)Förster Resonance Energy Transfer SensorsPh MonitoringPh SensingPh SensitivityPh SensorsPh-sensitive Probes
Abstract Monitoring the pH in tumor lesions provides abundant physiological information. However, currently developed pH sensors only achieve sensitive detection in the settled response region around the pH transition point (pH t ). To realize tumor pH monitoring with high sensitivity within a wider response region, reported here are serial pH t adjustable sensors (pTAS) that simply regulate the component ratio of second near‐infrared (NIR‐II) emission aza‐BODIPY (NAB) donor and pH sensitive rhodamine‐based pre‐acceptor (NRh) in Förster resonance energy transfer system. Combining the pH response regions of pTAS, a twofold widened pH detection range (6.11–7.22) is obtained compared to the pH t settled sensor (6.38–6.94). With an adjustable pH t , in vivo tumor pH increase and decrease processes could be dynamically visualized through dual‐channel ratiometric bioimaging within the NIR‐II window, with a coefficient of variation under 1 % compared to the standard pH meter.
33
Metabolic Heterogeneity in Human Lung Tumors
Christopher T. Hensley, Brandon Faubert, Qing Yuan et al. · Cell · 2016 · 1.1K citations · Full text
Medicine, Cancer Biology, Oncology +14