Manipulation Under Anaesthetic of Children's Fractures: Use of the Image Intensifier Reduces Radiation Exposure to Patients and Theatre Personnel

W. N. W. Keenan, A. F. Woodward, David C. Price, K. Eckloff, James Richards, J. Powell, S. Shanahan

Journal of Pediatric Orthopaedics · 1996 · 12 citations · 13 references

Concepts

Abstract

Summary During simulated manipulation of children's forearm fractures, levels of scattered radiation from both plain radiographs and an image intensifier in different modes were measured at various sites on the surgeon, anaesthetist, radiographer, and patient both with and without recommended shielding. By using fluoroscopy in the pulsed screening mode but allowing only single pulses to occur, radiation levels could be substantially reduced to the eye, thyroid, and gonads of all those exposed. The radiographer and the anaesthetist were so far from the source and guarded by various pieces of equipment that levels were almost unrecordable. Effective dose equivalent for the surgeon using pulsed mode, based on circa six pulses per manipulation, during 100 manipulations per year, would equate to 1 μSv even in the unshielded state (<0.1 μSv shielded), which is ≈1/1,000 of background radiation at sea level. Because the current dose limit is 50 mSv (50,000 μSv) per year for employees, we are many orders of magnitude in the safety zone.

References

13