Journal of Bone and Joint Surgery · 1998 · 321 citations · 22 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryOrthopedic RehabilitationOrthopedicsPhysical ActivityArthroplasty RehabilitationGait AnalysisGait AssessmentGait EvaluationLower Extremity RehabilitationPhysical Activity AssessmentActivity Level MonitoringActivity MonitoringGaitGait Analysis After Knee ArthroplastyReplacementStep CountingTotal Joint ArthroplastyWalking
Use of a joint replacement, rather than just time in situ, drives polyethylene wear, and individual differences in walking activity can cause substantial variability in wear rates. The study aims to determine whether a quantitative pedometer‑based assessment can prognostically inform joint prosthesis survival. Researchers recorded daily step counts with a digital pedometer in 111 non‑randomized patients who had undergone total hip or knee replacement, averaging 4,988 steps per day, corresponding to roughly 0.9 million gait cycles per joint annually. Walking activity spanned a 45‑fold range, with younger and male patients walking 30–40 % more on average; the high variability suggests pedometer data could predict polyethylene wear and aid outcome evaluations.
Accumulating data suggest that the amount of use, and not simply the duration in situ, influences the wear and survival of total joint replacements. An electronic, digital pedometer was used to record the number of steps taken by 111 non-randomized volunteers who had had at least one total hip or knee replacement.The patients averaged 4988 steps per day, which extrapolates to approximately 0.9 million cycles per year for each joint of the lower extremity. Average activity ranged widely from 395 to 17,718 steps per day, an approximately forty-five-fold difference. The most active patient walked more than 3.5 times the average number of steps per day. Age was significantly associated with activity (p = 0.048), but there was a high degree of variability (standard deviation, 3040 steps per day). Patients who were less than sixty years old walked 30 per cent more on average than those who were sixty years old or more (p = 0.023). Men walked 28 per cent more on average than women (p = 0.037), and men who were less than sixty years old walked 40 per cent more on average than the rest of the patients (p = 0.011). These data indicate that individual differences in the activity of the patient can be a substantial source of variability in rates of polyethylene wear in vivo.The pedometer is an inexpensive investigational tool with many potential applications, including standardizing wear measurements of joint replacements on the basis of gait cycles rather than time. This quantitative approach may provide prognostic information regarding the survival of joint prostheses. Pedometer data may also be useful for quantitative assessment of walking ability in outcome studies.
22