Journal of Endovascular Therapy · 2000 · 29 citations · 21 references
MedicineOrthopedic SurgerySurgeryCardiothoracic SurgeryUrologic SurgeryVascular SurgeryAneurysm RepairAortic Aneurysm RepairAortic DiseaseAortic SurgeryEndovascular SurgeryStent PlacementElective Aortic Aneurysm RepairEndovascular Aortic Aneurysm RepairRenal Artery Aneurysm InterventionRenal Artery StentingStent Graft PlacementStent-assisted Aneurysm Treatment
Purpose: To evaluate the feasibility and efficacy of a newly designed stent-graft placed across the renal arteries for exclusion of abdominal aortic aneurysms (AAAs) with short or tortuous proximal necks. Methods: Among a group of AAA patients treated with endovascular grafting, 5 had tortuous proximal necks and 13 had necks <20 mm (mean 13 mm). In these 18 cases, a 2-to 3-cm uncovered segment of the stent-graft was placed transrenally using a catheter inserted into the renal artery as a guide for graft margin positioning. A newly designed stent-graft was constructed from a custom-made spiral Z-stent covered with a thin-walled Dacron material; the endografts were deployed through 16-F (aortoaortic model) or 18-F sheaths (bifurcated devices). Renal function was assessed by preoperative and postoperative measurement of urea nitrogen and creatinine. Aneurysm exclusion and renal artery patency were evaluated during follow-up using spiral computed tomography and angiography. Results: The stent-grafts were correctly placed at the intended site in all 18 patients. Renal function was not affected except transiently in 1 patient who developed bilateral renal artery stenoses 24 hours after the procedure; Palmaz stents were deployed in each renal artery to reestablish satisfactory blood flow. Of the 33 renal arteries crossed by the bare stent-graft segment, all were patent over a mean 14-month follow-up (range 7–24), including the patient with Palmaz stents implanted for postprocedural renal stenosis. Complete aneurysm exclusion was maintained in 15 (83%) of 18 patients; proximal leaks persisted in 3 patients, including 2 with severely angled proximal necks. Conclusions: Transrenal placement of the uncovered leading edge of custom-made spiral Z-stent—based endografts appears feasible and clinically effective in the treatment of AAAs with short or tortuous proximal necks.
21
Wesley S. Moore, Vikram S. Kashyap, Candace L. Vescera et al. · Annals of Surgery · 1999 · 213 citations · Full text
Medicine, Surgery, Orthopedics +16
Ph. Cuypers, Jacob Buth, Peter L. Harris et al. · European Journal of Vascular and Endovascular Surgery · 1999 · 168 citations
Percutaneously placed endovascular grafts for aortic aneurysms: feasibility study.
David R. Mirich, K C Wright, S Wallace et al. · Radiology · 1989 · 163 citations