Journal of Pediatric Orthopaedics · 2003 · 164 citations · 6 references
MedicineOrthopaedic SurgeryRehabilitation MedicineMovement AnalysisNeurorehabilitationRehabilitationCerebral PalsyClinical Movement AssessmentGait AnalysisGait AssessmentGait BiomechanicsGait EvaluationCerebral Palsy BiomechanicsClinical Gait AnalysisClinical Gait AssessmentGait FunctionHuman Gait AnalysisInstrumented Movement AnalysisInterobserver Reliability AssessmentThree-dimensional Gait Analysis
Complex gait analysis systems are not generally available worldwide, and no simple system of assessing gait by observation has been validated specifically for use in patients with cerebral palsy. The authors have developed a visual gait analysis score for use in cerebral palsy. Videotaped sequences of patients were recorded before and after surgery as part of a three-dimensional gait study using a Vicon (Oxford, U.K.) gait analysis system. The score demonstrated good intraobserver and interobserver reliability. The numeric values of the score elements correlated well with the measurements obtained from instrumented gait analysis for the same patients, and the score was able to detect postoperative change.
6
The Measurement of Observer Agreement for Categorical Data
J. Richard Landis, Gary G. Koch · Biometrics · 1977 · 78.9K citations · Full text
Reliability of Observational Kinematic Gait Analysis
David E. Krebs, Joan E. Edelstein, Sidney Fishman · Physical Therapy · 1985 · 303 citations
Susan J. Hillman, ME Hazlewood, I.R. Loudon et al. · Gait & Posture · 1998 · 18 citations