Concepedia

Publication | Closed Access

Comparison of Fiberglass and Other Polymeric Well Casings, Part III. Sorption and Leaching of Trace‐Level Metals

15

Citations

8

References

1998

Year

Abstract

Abstract This series of experiments was initiated to determine the overall suitability of three alternative polymeric well casing materials (fluorinated ethylene propylene [FEP], fiberglass‐reinforced epoxy [FRE], and fiberglass‐reinforced plastic [FRP]) for use in ground water monitoring wells and to compare these materials with polyvinyl chloride (PVC) and polytetrafluoroethylene (PTFE) well casings. This paper focuses on sorption and leaching of metals. Generally, the fiberglass materials leached more metal contaminants than PVC, FEP, and PTFE. However, with one exception (Pb leaching from FRP), leached concentrations were below maximum allowable limits set by the U.S. Environmental Protection Agency (EPA) for drinking water. With respect to sorption, none of the polymers sorbed the anions tested, but all of them sorbed one or more of the cations tested. FEP and PTFE were much less sorptive than the other materials.