Anesthesia & Analgesia · 1999 · 58 citations · 8 references
Veterinary MedicineAnesthesiologyAnesthesiaAnesthetic TechniquesLocal AnesthesiaAnalgesiaAspiration RiskEpidural AnesthesiaGeneral Anesthetic AgentsAnesthetic Drug InfusionEpidural Catheter PlacementEpidural Test DoseIntravenous Bolus InjectionLabor Epidural AnalgesiaLabor Epidural PlacementLocal Anesthetic InfusionPharmacologic Labor Analgesia
Aspiration reliably detects almost all IV multiorifice epidural catheters.Although a supplemental epinephrine 15-[micro sign]g test dose may detect the rare IV catheter that does not yield blood on aspiration, false-positive epinephrine responses may cause some women to unnecessarily undergo repeat epidural catheter insertion. We evaluated 532 consecutive eligible patients requesting neuraxial labor analgesia. Patients were excluded if they had a contraindication to epinephrine or if they received intrathecal sufentanil/bupivacaine. Multiorifice catheters were inserted 4-6 cm into the epidural space as part of an epidural (n = 305) or combined spinal-epidural (n = 270) technique. We used aspiration, a lidocaine/epinephrine test dose, and bolus injection or infusion of dilute bupivacaine/sufentanil solutions to systematically determine IV, intrathecal, or epidural catheter location. Aspiration alone detected 47 of 48 intravascular catheters. There were 10 positive epinephrine responses: 2 were true positives, 7 were falsely positive (subsequent local anesthetic injection/infusion produced bilateral sensory change and analgesia), and 1 catheter was removed without further testing. Aspiration detected almost all intravascular catheters. Although the epinephrine test dose did detect one catheter that proved to be in a blood vessel, 87.5% of positive responses occurred in women without intravascular catheters. Implications: Epidural catheters may enter a blood vessel. Many clinicians use epinephrine to detect these catheters. Because aspiration alone detects almost all IV multiorifice catheters in laboring women, a subsequent epinephrine test dose may be unnecessary. (Anesth Analg 1999;88:1073-6)
8
The Components of an Effective Test Dose Prior to Epidural Block
Daniel C. Moore, Manbir S. Batra · Anesthesiology · 1981 · 243 citations · Full text
Limitations of Epinephrine as a Marker of Intravascular Injection in Laboring Women
Barbara L. Leighton, Mark C. Norris, Mitchel B. Sosis et al. · Anesthesiology · 1987 · 117 citations · Full text
Medicine, Gynecology, Obstetrics +11
Labor Epidural Analgesia without an Intravascular “Test Dose”
Mark C. Norris, Steven T. Fogel, Hiroko Dalman et al. · Anesthesiology · 1998 · 81 citations · Full text
Medicine, Anesthesiology, Obstetrics +14