Harmonic analysis of current waveforms using optical current sensor

Craig Michie, Andrew Cruden, Paweł Niewczas, W.I. Madden, J.R. McDonald, M. Gauduin

IEEE Transactions on Instrumentation and Measurement · 2002 · 11 citations · 4 references

Concepts

Abstract

This paper reports on the research and development of an optical current sensor for harmonic analysis within the electricity supply network. The device has a measurement capability, limited by the sampling frequency of the analog-to-digital converter, to around 20 kHz. We report on experimental verification of these measurements up to the 60th harmonic (3 kHz).

References

4