Accurate Flow-Out Measurements for Kick Detection, Actual Response to Controlled Gas Influxes

J. J. Orban, K.J. Zanker

Proceedings of SPE/IADC Drilling Conference · 1988 · 14 citations · 0 references

Concepts

Abstract

Accurate Flow-Out Measurements for Kick Detection, Actual Response to Controlled Gas Influxes J.J. Orban; J.J. Orban Anadrill/Schlumberger Search for other works by this author on: This Site Google Scholar K.J. Zanker K.J. Zanker Anadrill/Schlumberger Search for other works by this author on: This Site Google Scholar Paper presented at the IADC/SPE Drilling Conference, Dallas, Texas, February 1988. Paper Number: SPE-17229-MS https://doi.org/10.2118/17229-MS Published: February 28 1988 Cite View This Citation Add to Citation Manager Share Icon Share Twitter LinkedIn Get Permissions Search Site Citation Orban, J.J., and K.J. Zanker. "Accurate Flow-Out Measurements for Kick Detection, Actual Response to Controlled Gas Influxes." Paper presented at the IADC/SPE Drilling Conference, Dallas, Texas, February 1988. doi: https://doi.org/10.2118/17229-MS Download citation file: Ris (Zotero) Reference Manager EasyBib Bookends Mendeley Papers EndNote RefWorks BibTex Search Dropdown Menu toolbar search search input Search input auto suggest filter your search All ContentAll ProceedingsSociety of Petroleum Engineers (SPE)SPE/IADC Drilling Conference and Exhibition Search Advanced Search AbstractEarly reliable detection using, delta-flow offers the best approach to reducing the hazard associated with well kicks.This paper describes the performance of a recently introduced return-line flowmeter for kick detection.Controlled gas kicks were generated in a 1000 meter (3300 ft.) well and measurements performed. With the use of the new flow-out sensor, kicks were always detected a few minutes after the kick started downhole.The new flow sensor allows direct measurement of influx during a "flow check" procedure.This accurate flow-out measurement, together with the traditional flow-in evaluation from a pump stroke counter, is sufficient for kick or loss detection on most rigs when associated with continuous trend analysis of the variations in the ratio between flow-in and flow-out.IntroductionDrilling safety can be significantly improved by early kick detection. Accurate delta-flow measurement is the key to fast reliable detection. The full pipe flow pumped into the well (flow-in) can be measured quite accurately by several devices (ref. 6). The measurement of flow in the return line is more difficult as it is "open-channel" flow (ref. 4 and 5). Our solution was to develop a new ultra-sonic flow sensor, which was recently introduced to the market (ref. 6).Combining ultrasonic flow-out measurement with a UNIVERSAL (ref. 3) flow-in measurement (table 1), the delta-flow during drilling can be measured with an accuracy of 25 GPM (100 L/Min). This is believed to be the most accurate and reliable method for kick detection presently available. It is better than the required normal specification (ref. 1 and 2), of between 25 to 50 GPM (100 to 200 L/Min).Unlike electromagnetic meters, the system is not limited to water based muds.This paper discusses the performance of the ultrasonic flow-out sensor for kick detection.P. 445^ Keywords: influx, upstream oil & gas, actual response, accurate flow-out measurement, real time system, ultrasonic flow-out sensor, detection, return line, flow-out measurement, triplex efficiency Subjects: Pressure Management, Well control This content is only available via PDF. 1988. IADC/SPE Drilling Conference You can access this article if you purchase or spend a download.