Proceedings of SPE Annual Technical Conference and Exhibition · 2001 · 31 citations · 0 references
EngineeringEarth SciencesPetroleum EngineeringMultiphase FlowWell LoggingWell TestingFlow MetrologyFormation TestingMultiphase Flow In ReservoirsOil Well TestingWell HydraulicsWellbore FlowFlowing Well TestingFluid Properties CharacterizationMeasuring Of Multiphase FlowMetering Of Multiphase FlowMultiphase Flow DynamicsMultiphase Flow MeasurementMultiphase Flow PropertiesVolumetric Flow Rate
Multiphase Flowmeters in Well Testing Applications B.C. Theuveny; B.C. Theuveny Schlumberger Oilfield Services Search for other works by this author on: This Site Google Scholar G. Segeral; G. Segeral Schlumberger Oilfield Services Search for other works by this author on: This Site Google Scholar B. Pinguet B. Pinguet Schlumberger Oilfield Services Search for other works by this author on: This Site Google Scholar Paper presented at the SPE Annual Technical Conference and Exhibition, New Orleans, Louisiana, September 2001. Paper Number: SPE-71475-MS https://doi.org/10.2118/71475-MS Published: September 30 2001 Cite View This Citation Add to Citation Manager Share Icon Share Twitter LinkedIn Get Permissions Search Site Citation Theuveny, B.C., Segeral, G., and B. Pinguet. "Multiphase Flowmeters in Well Testing Applications." Paper presented at the SPE Annual Technical Conference and Exhibition, New Orleans, Louisiana, September 2001. doi: https://doi.org/10.2118/71475-MS Download citation file: Ris (Zotero) Reference Manager EasyBib Bookends Mendeley Papers EndNote RefWorks BibTex Search Dropdown Menu toolbar search search input Search input auto suggest filter your search All ContentAll ProceedingsSociety of Petroleum Engineers (SPE)SPE Annual Technical Conference and Exhibition Search Advanced Search AbstractDual-energy spectral gamma ray / Venturi multiphase flowmeters present an efficient and cost-effective means of testing wells in many field applications. A simple, efficient and quick procedure optimizes the utilization of these types of multiphase flow meters for well testing. This paper presents the field operating procedures for installing and using multiphase flowmeter and gives practical recommendations for performing well tests with or without a reference, such as a separator. The analysis of 415 multiphase well tests performed worldwide has provided some insights into the accuracy achieved in the field and has led to some recommendations for the test design.The ability of a multiphase flowmeter to perform a measurement in the absence of a flowing reference is essential to well testing in most applications. Furthermore, the high mobility of the equipment (with up to three wells tested in three different locations per day) allows a very efficient and short turn around time for installation and operation.The parameters required to perform the setup of a meter fall into two categories: meter static empty pipe reference and fluid properties. A detailed review of each parameter is presented along with its sensitivities when determining the flow rates of oil, gas and water. A description of the field procedure used to determine each setup parameter is provided and a series of field examples are presented that illustrate the efficiency of using multiphase flowmeters for well testing.IntroductionThe use of multiphase flowmeters in well testing is not new. Early developments (in the 1980s) of multiphase flowmeters have been geared towards the testing of wells mostly in the United States. In the early 1990s, the engineering of multiphase flowmeters took a form more oriented towards pure instrumentation and metering applications, with many operating companies metering departments and research centers working in close collaboration with various suppliers to advance the technologies.1–18 Key technology breakthroughs, mostly in the determination of fractions combined with a better understanding of multiphase flow dynamics, have improved the overall confidence in the techniques and led several operators to implement field applications of multiphase flowmeters. Most of the meters deployed in the oil field to date are installed permanently in production systems. Such applications will not be discussed here. We will focus on the challenges of mobile well testing operations, supplied as a full service package by a service company.Review of benefits of multiphase flowmetersTraditionally well testing is performed using single-phase flowmeters installed on the oil, gas and water outlet of test separators. Large pressure vessels, important hydrocarbon inventory in piping and separator bodies, heavy lift, large rig-up and operating crews have been some of the chores attached to well testing. Refs. 16 and 19 illustrated the benefits of multiphase flowmeters over test separators in some field applications. Although some tradeoffs are inevitable, overall multiphase flowmeters bring an efficient solution to well testing measurements. Their main benefits are gains inSafetyLogisticsDuration of the operationData quality Keywords: wlr, input parameter, determination, production control, fraction, theuveny, real time system, flow rate, ségéral, flow metering Subjects: Well & Reservoir Surveillance and Monitoring, Downhole and wellsite flow metering This content is only available via PDF. 2001. Society of Petroleum Engineers You can access this article if you purchase or spend a download.