IEEE Access · 2022 · 12 citations · 34 references
EngineeringBiomedical EngineeringBiomedical ImagingComputer VisionMachine VisionInfrared Remote SensingTemperature MeasurementThermal Remote SensingThermal SensorsAutomatic Landmark DetectionBody TemperatureFacial Landmark DetectionLandmark DetectionRespiratory RateRespiratory Rate MeasurementThermal ImagingThermal Sensing
Infrared thermographs (IRTs, also called thermal cameras) have been used to remotely measure elevated body temperature (BT) and respiratory rate (RR) during infectious disease outbreaks, such as COVID-19. To facilitate the fast measurement of BT and RR using IRTs in densely populated venues, it is desirable to have IRT algorithms that can automatically identify the best facial locations in thermal images to extract these vital signs. The IEC 80601-2-59:2017 standard suggests that the regions medially adjacent to the inner canthi of the eyes are robust BT measurement sites. The nostril regions, on the other hand, are often used for RR estimation. However, it is more difficult to automatically identify inner canthi and nostrils in thermal images than in visible-light images, which are rich with exploitable features. In this paper, a unique system that can detect inner canthi and outer nostril edges directly in thermal images in two phases is introduced. In Phase I, original thermal images were processed in four different ways to enhance facial features to facilitate inner canthus and nostril detection. In Phase II, landmarks of the inner canthi and outer nostril edges were detected in two steps: (1) face detection using the Single Shot Multibox Detector (SSD) and (2) facial landmark detection to locate the inner canthi and outer nostril edges. The face detection, facial landmark detection, and overall system accuracies were evaluated using the intersection over union, normalized Euclidean distance, and success detection rate metrics on a set of 36 thermal images collected from 12 subjects using three different IRTs. Additional validation was performed on a subset of 40 random thermal images from the publicly available Tufts Face Database. The results revealed that the processed images—referred to as ICLIP images—yielded the highest landmark localization accuracy from the four types of processed thermal images, verifying that the system can automatically and accurately estimate the inner canthus and nostril locations in thermal images. The proposed system can be applied in IRT algorithms to provide reliable temperature measurements and RR estimates during infectious disease outbreaks.
34
Rapid object detection using a boosted cascade of simple features
Paul Viola, Michael Jones · 2005 · 18.2K citations
One millisecond face alignment with an ensemble of regression trees
Vahid Kazemi, Josephine Sullivan · 2014 · 2.8K citations · Full text
300 Faces In-The-Wild Challenge: database and results
Christos Sagonas, Epameinondas Antonakos, Georgios Tzimiropoulos et al. · Image and Vision Computing · 2016 · 749 citations · Full text