Diabetes Technology & Therapeutics · 2022 · 25 citations · 14 references
MedicineEndocrinologyInternal MedicineDiabetologyGeneral Internal MedicineGood Clinical PracticeDiabetes ManagementDiabetes MellitusDiabetic KetoacidosisGlycemic ControlHypoglycemia ManagementInsulin TherapyContinuous Subcutaneous Insulin InfusionGlucose MonitoringInsulin Administration SafetyInsulin Infusion SafetyInsulin Infusion SetsIntravenous Insulin InfusionIntravenous Insulin TherapySevere Hypoglycemia Management
Background: Standard insulin infusion sets (IISs) are to be replaced every 2 to 3 days to avoid complications and diabetic ketosis due to set failure. This pivotal trial evaluated the safety and performance of a new extended-wear infusion set (EIS) when used for 7 days by adults with type 1 diabetes (T1D). Methods: This single-arm, nonrandomized trial enrolled adults (18–80 years of age) with T1D, who used their own MiniMed™ 670G system with insulin lispro or insulin aspart and the EIS for up to 7 days, across 12 consecutive wears. Safety endpoints included incidence of serious adverse events (SAEs), serious adverse device effects (SADEs), unanticipated adverse device effects (UADEs), severe hypoglycemia (SevHypo), severe hyperglycemia (SevHyper), diabetic ketoacidosis (DKA), and skin infection. The EIS failure rate due to unexplained hyperglycemia (i.e., suspected occlusion), the overall EIS survival rate, glycemic control outcomes (i.e., A1C, mean sensor glucose and time spent in established glucose ranges), total daily insulin delivered, and satisfaction with the EIS were determined. Results: The intention to treat population ( n = 259, 48% men, 45.0 ± 14.1 years) wore a total of 3041 EIS devices. No SADE, UADE, or DKA events was reported. Overall rates of SAEs, SevHypo, SevHyper, and skin infection were 3.8, 2.5, 104.1, and 20.1 events per 100 participant-years. The rate of EIS failure due to unexplained hyperglycemia at the end of day 7 was 0.1% (95% confidence interval [CI]: 0.03–0.51) and 0.4% (95% CI: 0.16–1.00) for insulin lispro and aspart use, respectively. Overall EIS survival rate at the end of day 7 was 77.8% (95% CI: 76.2–79.3), glycemic control did not change, and participants reported greater satisfaction with the EIS compared with standard IISs worn before the study ( P < 0.001). Conclusions: This investigation demonstrates that the EIS, when worn for up to 7 days, was safe and rated with high satisfaction, without adversely affecting glycemic control in adults with T1D. Clinical Trial Registration number: NCT04113694 ( https://clinicaltrials.gov/ct2/show/NCT04113694 ).
14
Volkmar H.R. Schmid, C Hohberg, Marcus Borchert et al. · Journal of Diabetes Science and Technology · 2010 · 96 citations · Full text
Randomized Trial of Infusion Set Function: Steel Versus Teflon
Parul J. Patel, Kari Benasi, Gina Ferrari et al. · Diabetes Technology & Therapeutics · 2013 · 89 citations
David Kerr, John Morton, Caroline Whately‐Smith et al. · Journal of Diabetes Science and Technology · 2008 · 59 citations · Full text
Medicine, Endocrinology, Diabetology +12