Journal of Chromatography B · 2022 · 17 citations · 19 references
PharmacyBiochemistryAnalytical ChemistryChromatographic AnalysisMass Spectrometric AnalysisBioanalytical Method ValidationChromatographic Data AnalysisChromatographyInstrumental AnalysisLipidomicsLiquid ChromatographyClinical LipidomicsCycle TimeLipid QuantificationLiquid Chromatography-mass SpectrometryLiquid Chromatography-mass Spectrometry AnalysisMass Spectrometry-based LipidomicsPolaritiesUntargeted Lipidomics
Untargeted lipidomics using liquid chromatography high-resolution mass spectrometry (LC-HRMS) was performed using polarity switching, and in positive and negative polarity separately on the same set of serum samples, and the performances of the methods were evaluated. Polarity switching causes an increase in the cycle time of the HRMS measurements (1.18 s/cycle vs 0.27 s/cycle), resulting in fewer data points across chromatographic peaks. The coefficient of variation (CV) was on average lower for the added isotopically labelled standards in pooled samples (QC) and patient samples using separate polarities (QC = 5.6%, samples = 12.5%) compared to polarity switching (QC = 8.5%, samples = 13.4%), but the difference was not statistically significant. For the endogenous features measured in the QCs polarity switching resulted in on average significantly higher CVs (3.80 (p = 4.25e-30) and 3.3 percentage points (p = 6.84e-40), for positive and negative modes, respectively) however still acceptable for an untargeted method (mean CVs of 17.9% and 12.2% in positive and negative modes respectively). A slightly larger number of endogenous features were detected using the separate polarities, but the large majority of features (>95%) were detected with both methodologies. The overlap of features detected in both positive and negative polarities was low (4.1%) demonstrating the importance of using both polarities for untargeted lipidomics. When investigating the effects of a treatment on multiple sclerosis patients it was found that both methodologies gave highly similar biological results, further confirming the applicability of polarity switching.
19
OpenMS: a flexible open-source software platform for mass spectrometry data analysis
Hannes Röst, Timo Sachsenberg, Stephan Aiche et al. · Nature Methods · 2016 · 751 citations
Magali Sarafian, Mathieu Gaudin, Matthew R. Lewis et al. · Analytical Chemistry · 2014 · 314 citations
An Efficient Single Phase Method for the Extraction of Plasma Lipids
Zahir H. Alshehry, Christopher K. Barlow, Jacquelyn M. Weir et al. · Metabolites · 2015 · 226 citations · Full text
Susanne B. Breitkopf, Stéphane J. H. Ricoult, Min Yuan et al. · Metabolomics · 2017 · 198 citations · Full text
Lipidomics: An analysis of cellular lipids by ESI-MS
Stephen Milne, Pavlina T. Ivanova, Jeffrey Forrester et al. · Methods · 2006 · 171 citations