ESC Heart Failure · 2022 · 27 citations · 29 references
MedicineCardiologySurgeryCardiothoracic SurgeryInterventional CardiologyPerioperative Outcomes ResearchCardiac Valve SurgeryMitral RegurgitationMitral Valve DiseaseMitral Valve InterventionTranscatheter Mitral Valve RepairTranscatheter Valve TherapyEdge-to-edge Valve RepairFunctional Class AssessmentHigh-risk Surgical PatientsMitraclip TherapyMitral Regurgitation Severity AssessmentMitral Valve Repair DevicesResidual Mitral RegurgitationTranscatheter Edge-to-edge Repair
AIMS: Mitral valve transcatheter edge-to-edge repair (TEER) has been established as a suitable alternative to mitral valve surgery in patients with severe mitral regurgitation (MR) and high surgical risk. The PASCAL system represents a novel device, potentially augmenting the toolkit for TEER. The aim of this study was to assess and compare short and 1 year safety and efficacy of the PASCAL and MitraClip systems for TEER. METHODS AND RESULTS: Procedural, short, and 1 year outcomes of a 1:2 propensity-matched cohort including 41 PASCAL and 82 MitraClip cases were investigated. Matching was based on clinical, laboratory, echocardiographic, and functional characteristics. The primary endpoints assessed were procedural success [as defined by the Mitral Valve Academy Research Consortium (MVARC)], residual MR, functional class, and a composite endpoint comprising death, heart failure hospitalization, and mitral valve re-intervention. We found for the PASCAL and the matched MitraClip cohort no significant differences in MVARC defined technical (90.2% vs. 95.1%, P = 0.44), device (90.2% vs. 89.0%, P = 1.0), or procedural (87.8% vs. 80.5%, P = 0.45) success rates. Accordingly, the overall MR reduction and improvement in New York Heart Association (NYHA) class were comparable (1 year follow-up: MR ≤ 2 95% vs. 93.6%, P = 1.0; NYHA ≤ 2 57.1% vs. 66.7%, P = 0.59). The composite outcome revealed no statistically significant difference between both devices (1 year follow-up: 31.7% vs. 37.8%, P = 0.55). Interestingly, we found at both short and 1 year follow-up a significantly higher rate of patients with none or trace MR in the PASCAL-treated cohort (short follow-up: 17.9% vs. 0%, P = 0.0081; 1 year follow-up: 25% vs. 0%, P = 0.0016). Conversely, the rate of aborted device implantations due to an elevated transmitral gradient was higher in PASCAL interventions (9.8% vs. 1.2%, P = 0.04). CONCLUSIONS: Transcatheter edge-to-edge repair using the PASCAL or MitraClip device results in favourable and comparable outcomes regarding safety, efficacy, and clinical improvement after 1 year.
29
2017 ESC/EACTS Guidelines for the management of valvular heart disease
Helmut Baumgartner, Volkmar Falk, Jeroen J. Bax et al. · European Heart Journal · 2017 · 6.3K citations · Full text
Medicine, Cardiology, Surgery +14
Burden of valvular heart diseases: a population-based study
Vuyisile T. Nkomo, Julius M. Gardin, Thomas N. Skelton et al. · The Lancet · 2006 · 4.8K citations
<b>MatchIt</b>: Nonparametric Preprocessing for Parametric Causal Inference
Daniel E. Ho, Kosuke Imai, Gary King et al. · Journal of Statistical Software · 2011 · 4.4K citations · Full text
Catherine M Otto, Rick A. Nishimura, Robert O. Bonow et al. · Circulation · 2020 · 3.6K citations · Full text
Transcatheter Mitral-Valve Repair in Patients with Heart Failure
Gregg W. Stone, JoAnn Lindenfeld, William T. Abraham et al. · New England Journal of Medicine · 2018 · 2.9K citations · Full text
Medicine, Cardiology, Surgery +11