Annals of Laboratory Medicine · 2022 · 30 citations · 19 references
MedicineHematologyPathologyDiagnostic PathologyHematopathologyRisk AssessmentPeripheral Blood MorphologyPeripheral Blood Smear InterpretationWhite Blood Cell DisordersFailure Mode AssessmentFailure Mode ClassificationLaboratory Test Risk AssessmentLeukocyte CountsPeripheral Blood Smear MorphologyRisk Priority NumberWhite Blood Cell Differential CountWhite Blood Cell Morphology
BACKGROUND: Digital morphology (DM) analyzers are increasingly being used for white blood cell (WBC) differentials. We assessed the laboratory efficiency of the Sysmex DI-60 system (DI-60; Sysmex, Kobe, Japan) in comparison with manual counting in leukopenic samples. METHODS: In total, 40 peripheral blood smear samples were divided into normal, mild leukopenia, moderate leukopenia, and severe leukopenia groups based on WBC count. In each group, the risk and turnaround time (TAT) were compared between DI-60 and manual counting. Risk was determined by failure mode and effect analysis using the risk priority number (RPN) score, and TAT was recorded for the analytical phase. RESULTS: Overall, DI-60 showed a five-fold lower risk (70 vs. 350 RPN) and longer TAT than manual counting. In severe leukopenic samples, DI-60 showed a shorter TAT/slide and a remarkably lower cell count/slide than manual counting. In all samples, the TAT/cell for DI-60 was substantially longer than that for manual counting (DI-60 vs. manual: total, 1.8 vs. 1.0 sec; normal, 1.5 vs. 0.7 sec; mild leukopenia, 1.9 vs. 0.9 sec; moderate leukopenia, 1.8 vs. 1.0 sec; severe leukopenia, 28.8 vs. 19.0 sec). CONCLUSIONS: This is the first comparative assessment of risk and TAT between DI-60 and manual counting in leukopenic samples. DI-60 decreases the laboratory risk and improves patient safety, but requires more time to count fewer cells, especially in severe leukopenic samples. DM analyzers should be applied selectively depending on the WBC count to optimize laboratory efficiency.
19
Liron Pantanowitz, John H. Sinard, Walter H. Henricks et al. · Archives of Pathology & Laboratory Medicine · 2013 · 603 citations · Full text
Medicine, Hematology, Pathology +16
Robert C. Hawkins · PubMed · 2007 · 278 citations
Health Professions, Performance Management, Healthcare Quality Improvement +15
Performance Evaluation of the CellaVision DM96 System
Alexander Kratz, Hans‐Inge Bengtsson, Jeanne E. Casey et al. · American Journal of Clinical Pathology · 2005 · 134 citations · Full text
Medicine, Hematology, Pathology +16
Laura Sciacovelli, Giuseppe Lippi, Zorica Šumarac et al. · Clinical Chemistry and Laboratory Medicine (CCLM) · 2016 · 120 citations · Full text