IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 2022 · 12 citations · 46 references
MedicineCardiologyPhysicsComputational Fluid DynamicsFluid DynamicsUltrasonographyDoppler UltrasoundFlow MeasurementUnsteady Flow VisualizationVascular ImagingVascular UltrasonographyVascular UltrasoundBifurcation Flow DynamicsCarotid Artery UltrasoundComputational Fluid Dynamics ValidationFlow Dynamics ImagingVascular Flow ImagingVascular Flow Velocity MeasurementVelocityVelocity Components
In this work, the accuracy of row–column tensor velocity imaging (TVI), i.e., 3-D vector flow imaging (VFI) in 3-D space over time, is quantified on a complex, clinically relevant flow. The quantification is achieved by transferring the flow simulated using computational fluid dynamics (CFD) to a Field II simulation environment, and this allows for a direct comparison between the actual and estimated velocities. The carotid bifurcation flow simulations were performed with a peak inlet velocity of 80 cm/s, nonrigid vessel walls, and a flow cycle duration of 1.2 s. The flow was simulated from two observation angles, and it was acquired using a 3-MHz 62+62 row–column addressed array (RCA) at a pulse repetition frequency ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${f}_{prf}$ </tex-math></inline-formula> ) of 10 and 20 kHz. The tensor velocities were obtained at a frame rate of 208.3 Hz, at <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${f}_{prf} = {10} ~\mathrm{kHz}$ </tex-math></inline-formula> , and the results from two velocity estimators were compared. The two estimators were the directional transverse oscillation (TO) cross correlation estimator and the proposed autocorrelation estimator. Linear regression between the actual and estimated velocity components yielded, for the cross correlation estimator, an <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${R}$ </tex-math></inline-formula> <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> value in the range of 0.89–0.91, 0.46–0.77, and 0.91–0.97 for the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${x}$ </tex-math></inline-formula> -, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${y}$ </tex-math></inline-formula> -, and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${z}$ </tex-math></inline-formula> -components, and 0.87–0.89, 0.40–0.83, and 0.91–0.96 when using the autocorrelation estimator. The results demonstrate that an RCA can, with just 62 receive channels, measure complex 3-D flow fields at a high volume rate.
46
Noninvasive assessment of pressure drop in mitral stenosis by Doppler ultrasound.
Liv Hatle, A. O. Brubakk, Arve Tromsdal et al. · Heart · 1978 · 550 citations · Full text
Philip J. Currie, J B Seward, Guy S. Reeder et al. · Circulation · 1985 · 517 citations · Full text