International Journal of Environmental Research and Public Health · 2022 · 48 citations · 30 references
Public HealthEnvironmental SciencesMeteorologyAir PollutionAtmospheric ScienceSensorsAir PollutantsAir Pollution MeasurementAir QualityAmbient Air QualityEnvironmental QualityParticulate MatterAccuracyAir Quality Sensor CalibrationAmbient Air Pollution MonitoringAmbient Air Quality MonitoringAtmospheric MonitoringLow-cost Air Quality SensorsLow-cost Air SensorsUrban Air Quality Monitoring
The emergence of low-cost air quality sensors may improve our ability to capture variations in urban air pollution and provide actionable information for public health. Despite the increasing popularity of low-cost sensors, there remain some gaps in the understanding of their performance under real-world conditions, as well as compared to regulatory monitors with high accuracy, but also high cost and maintenance requirements. In this paper, we report on the performance and the linear calibration of readings from 12 commercial low-cost sensors co-located at a regulatory air quality monitoring site in Dallas, Texas, for 18 continuous measurement months. Commercial AQY1 sensors were used, and their reported readings of O3, NO2, PM2.5, and PM10 were assessed against a regulatory monitor. We assessed how well the raw and calibrated AQY1 readings matched the regulatory monitor and whether meteorology impacted performance. We found that each sensor’s response was different. Overall, the sensors performed best for O3 (R2 = 0.36–0.97) and worst for NO2 (0.00–0.58), showing a potential impact of meteorological factors, with an effect of temperature on O3 and relative humidity on PM. Calibration seemed to improve the accuracy, but not in all cases or for all performance metrics (e.g., precision versus bias), and it was limited to a linear calibration in this study. Our data showed that it is critical for users to regularly calibrate low-cost sensors and monitor data once they are installed, as sensors may not be operating properly, which may result in the loss of large amounts of data. We also recommend that co-location should be as exact as possible, minimizing the distance between sensors and regulatory monitors, and that the sampling orientation is similar. There were important deviations between the AQY1 and regulatory monitors’ readings, which in small part depended on meteorology, hindering the ability of the low-costs sensors to present air quality accurately. However, categorizing air pollution levels, using for example the Air Quality Index framework, rather than reporting absolute readings, may be a more suitable approach. In addition, more sophisticated calibration methods, including accounting for individual sensor performance, may further improve performance. This work adds to the literature by assessing the performance of low-cost sensors over one of the longest durations reported to date.
30
Global estimates of mortality associated with long-term exposure to outdoor fine particulate matter
Richard T. Burnett, Hong Chen, Mieczysław Szyszkowicz et al. · Proceedings of the National Academy of Sciences · 2018 · 2.5K citations · Full text
Public Health, Environmental Sciences, Population Health Sciences +17
Laurent Spinelle, Michel Gerboles, Maria Gabriella Villani et al. · Sensors and Actuators B Chemical · 2015 · 491 citations · Full text
Engineering, Environmental Engineering, Environmental Sciences +17
Laurent Spinelle, Michel Gerboles, Maria Gabriella Villani et al. · Sensors and Actuators B Chemical · 2016 · 398 citations · Full text
Engineering, Environmental Engineering, Environmental Sciences +17