Means for Passive Inflow Control Upon Gas Breakthrough

Stephen Crow, Martin P. Coronado, R. K. Mody

Proceedings of SPE Annual Technical Conference and Exhibition · 2006 · 21 citations · 0 references

Concepts

Abstract

Means for Passive Inflow Control Upon Gas Breakthrough Stephen Lee Crow; Stephen Lee Crow Baker Oil Tools Search for other works by this author on: This Site Google Scholar Martin P. Coronado; Martin P. Coronado Baker Oil Tools Search for other works by this author on: This Site Google Scholar Rustom Khodadad Mody Rustom Khodadad Mody Baker Hughes Search for other works by this author on: This Site Google Scholar Paper presented at the SPE Annual Technical Conference and Exhibition, San Antonio, Texas, USA, September 2006. Paper Number: SPE-102208-MS https://doi.org/10.2118/102208-MS Published: September 24 2006 Cite View This Citation Add to Citation Manager Share Icon Share Twitter LinkedIn Get Permissions Search Site Citation Crow, Stephen Lee, Coronado, Martin P., and Rustom Khodadad Mody. "Means for Passive Inflow Control Upon Gas Breakthrough." Paper presented at the SPE Annual Technical Conference and Exhibition, San Antonio, Texas, USA, September 2006. doi: https://doi.org/10.2118/102208-MS Download citation file: Ris (Zotero) Reference Manager EasyBib Bookends Mendeley Papers EndNote RefWorks BibTex Search nav search search input Search input auto suggest search filter All ContentAll ProceedingsSociety of Petroleum Engineers (SPE)SPE Annual Technical Conference and Exhibition Search Advanced Search AbstractGenerally, horizontally completed oil producers are susceptible to localized gas coning during their life due to the gas/oil contact encroaching the well bore. Even a small difference in permeability and/or relative permeability along the well bore can result in gas coning, which impacts oil production and gas handling issues. Production optimization can be achieved by selectively shutting in areas where gas coning has broken into the wellbore, thus improving drainage efficiency.A new system has been developed to passively sense gas inflow into the well. Once gas is detected in sufficient levels a valve is activated which shuts off the flow path into the well. The valve is designed to detect fluid density changes, and will activate once a predetermined decrease in production fluid density is reached, indicating gas coning. Incorporated in a sand face screen completion, each screen joint includes a phase-sensitive valve that enables it to work independently of the others. This approach has the benefit of shutting off unwanted gas inflow without the need for costly well intervention. Used in conjunction with zone isolation packers to eliminate annular flow, flow normalization can be achieved across the production interval1. The design can also be adapted to shut off water flow, as well as gas, in the event of water coning into the wellbore.This paper will detail the development process of this new passive gas shut-off valve, including laboratory testing performed to qualify the technology. Plans for full-scale two-phase flow testing, conducted in cooperation with a major North Sea operator, will also be discussed.IntroductionControlling inflow into long, extended-reach horizontal wellbores has received significant attention within the past 10 years. A considerable amount of test data and actual field installations have shown that balancing inflow over the entire production interval results in enhanced oil recovery and a delay in gas and water coning2. The advent of the Inflow Control Device (ICD), which is patented by Hydro, has revolutionized the means by which long horizontal wells are produced. The ICD is essentially a flow restriction device integral to each screen joint. By restricting free flow into the screen a normalizing effect is created by which all screen joints contribute equally to the production inflow. The tendency for greater production from the heal of the wellbore is eliminated3. In non-gravel packed applications the ICD also eliminates annular flow around the screens and creates a balanced radial flow regime4.The ICD design best suited for a long service life uses a helical flow channel located in the screen assembly between the filter cartridge and the opening into the screen body. The helical flow channel creates a very precise, and repeatable, pressure drop for a specified fluid density and flow rate. The flow restriction is created by the fluid friction with the walls of the helical channels. The number of channels and their length can vary to create the desired flow restriction. This design maintains fluid flow velocity relatively low, when compared to an orifice-type restrictor, and results in very small erosion potential. This yields a product with a long service life.Typically for horizontal wells in uniform formations the flow normalizing effect created by the ICD delays the onset of gas and/or water coning along the whole horizontal section. However, there are uncertainties with respect to drilling accuracy, and in heterogeneous formations localized gas breakthrough will impair oil production. This is due to many variables such as the static effects of absolute permeability, permeability distribution and geometry (sand thickness and well elevation), dynamic effects of the wells distance to liquid contacts, global moments based on aquifer communication to surrounding aquifers and gas cap, neighboring wells and past production history.To prevent gas influx into the well once initial gas breakthrough does occur, a density-sensitive valve (patent pending) has been designed to compliment the ICD. This enhancement of the existing ICD design is designated Autonomous Inflow Control Device (AICD). Keywords: Reservoir Surveillance, flow metering, production control, conformance improvement, Upstream Oil & Gas, production monitoring, production logging, completion, Fixture, gas breakthrough Subjects: Well & Reservoir Surveillance and Monitoring, Reservoir Fluid Dynamics, Improved and Enhanced Recovery, Production logging, Downhole and wellsite flow metering, Flow in porous media, Conformance improvement This content is only available via PDF. 2006. Society of Petroleum Engineers You can access this article if you purchase or spend a download.