IEEE Journal of Solid-State Circuits · 2021 · 41 citations · 38 references
EngineeringBioengineeringBiomedical EngineeringBiomemsLow-power DesignMicroelectromechanical SystemsImplant TechnologyImplantable Biomedical DevicesImplantable MicrodevicesImplantable MicrosystemsNeurostimulationWireless Power TransferBiomedical ImplantsBiomedical Wireless Power TransferDevice SynchronizationImplantable Wireless Power TransferMagnetoelectric EffectMiniaturized Implantable SystemsSystem-on-chip ArchitectureWireless Power Transfer For Implants
This article presents a hardware platform including stimulating implants wirelessly powered and controlled by a shared transmitter (TX) for coordinated leadless multisite stimulation. The adopted novel single-TX, multiple-implant structure can flexibly deploy stimuli, improve system efficiency, easily scale stimulating channel quantity, and relieve efforts in device synchronization. In the proposed system, a wireless link leveraging magnetoelectric (ME) effect is co-designed with a robust and efficient system-on-chip (SoC) to enable reliable operation and individual programming of every implant. Each implant integrates a 0.8-mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> chip, a 6-mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ME film, and an energy storage capacitor within a 6.2-mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> size. ME power transfer is capable of safely transmitting milliwatt power to devices placed several centimeters away from the TX coil, maintaining good efficiency with size constraints, and tolerating 60°, 1.5-cm misalignment in angular and lateral movement. The SoC robustly operates with 2-V source amplitude variations that spans a 40-mm TX-implant distance change, realizes individual addressability through physical unclonable function (PUF) IDs, and achieves 90% efficiency for 1.5–3.5-V stimulation with fully programmable stimulation parameters.
38
Cardiac Resynchronization in Chronic Heart Failure
William T. Abraham, Westby G. Fisher, Andrew L. Smith et al. · New England Journal of Medicine · 2002 · 4.6K citations · Full text
Susan J. Harkema, Yury Gerasimenko, Jonathan E. Hodes et al. · The Lancet · 2011 · 1.2K citations
Stem cell differentiation trajectories in <i>Hydra</i> resolved at single-cell resolution
Stefan Siebert, Jeffrey A. Farrell, Jack F. Cazet et al. · Science · 2019 · 411 citations · Full text