Frontiers in Medicine · 2021 · 43 citations · 18 references
MedicineOphthalmologySurgeryMyopia ManagementOphthalmic SurgeryRefractive SurgeryAstigmatism CorrectionMyopia CorrectionPhakic Intraocular LensesPostoperative Refractive OutcomesPreoperative Refractive EvaluationRefractive ErrorAstigmatismHigh Myopia CorrectionImplantable Collamer LensMyopic Astigmatism CorrectionPhakic Intraocular Lens PlacementPosterior Chamber Intraocular LensesPostoperative Visual AcuityPostoperative Visual Outcome Assessment
Purpose: To assess the 8-year clinical outcomes of implantation of an implantable collamer lens (ICL) with a central port (KS-Aquaport; EVO-ICL) for moderate to high myopia and myopic astigmatism. Methods: This retrospective study comprised a total of 177 eyes of 106 patients with spherical equivalents of −7.99 ± 3.33 D [mean ± standard deviation], who underwent EVO-ICL implantation. We evaluated the safety, efficacy, predictability, stability, and adverse events of the surgery, at 1 month, and 1, 2, 4, 6, and 8 years postoperatively. Results: The logarithm of the minimal angle of resolution (LogMAR) uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were −0.07 ± 0.17 and −0.20 ± 0.09, respectively, at 8 years postoperatively. The safety and efficacy indices were 1.18 ± 0.24 and 0.89 ± 0.28, respectively. At 8 years, 83 and 93% eyes were within ± 0.5 D and ± 1.0 D of the targeted correction, respectively. Change in manifest refraction from 1 month to 8 years postoperatively was −0.13 ± 0.30 D. Three eyes (1.7%) that developed cataracts had a slight pre-existing peripheral anterior subcapsular cataract formation required simultaneous ICL extraction and cataract surgery at 2 or 3 years or ICL size change (1 size up) at 7 years postoperatively. We found that neither significant intraocular pressure (IOP) rise (including pupillary block) nor significant endothelial cell loss occurred in any case throughout the 8-year observation period. Conclusions: Current ICL implantation with central port technology offered good continuous outcomes for all measures of safety, efficacy, predictability, and stability for correcting moderate to high myopic errors over a long period, thereby suggesting its long-term viability as a surgical approach for the treatment of such eyes.
18
Kimiya Shimizu, Kazutaka Kamiya, Akihito Igarashi et al. · British Journal of Ophthalmology · 2011 · 147 citations · Full text
Medicine, Ophthalmology, Surgery +17