High-Intensity Focused Ultrasound (HIFU) Focal Therapy for Localized Prostate Cancer with MRI-US Fusion Platform

Chi‐Hang Yee, Peter Ka‐Fung Chiu, Jeremy Yuen‐Chun Teoh, Chi‐Fai Ng, Chi‐Kwok Chan, See‐Ming Hou

Advances in Urology · 2021 · 17 citations · 24 references

DOIFull text

Open access

Concepts

Abstract

Objective. The study aimed at investigating the outcome of prostate HIFU focal therapy using the MRI-US fusion platform for treatment localization and delivery. Methods. It is a prospectively designed case series of HIFU focal therapy for localized prostate cancer. The inclusion criteria include clinical tumor stage ≤T2, visible index lesion on multiparametric MRI less than 20 mm in diameter, absence of Gleason 5 pattern on prostate biopsy, and PSA ≤ 20 ng/ml. HIFU focal therapy was performed in the conventional manner in the beginning 50% of the series, whereas the subsequent cases were performed with MRI-US fusion platform. The primary outcome was treatment failure rate which is defined by the need of salvage therapy. Secondary outcomes included tumor recurrence in follow-up biopsy, PSA change, perioperative complications, and postoperative functional outcomes. Results. Twenty patients underwent HIFU focal ablation. HIFU on an MRI-US fusion platform had a trend of a longer total operative time than the conventional counterpart (124.2 min vs. 107.1 min, <a:math xmlns:a="http://www.w3.org/1998/Math/MathML" id="M1"> <a:mi>p</a:mi> <a:mo>=</a:mo> <a:mn>0.066</a:mn> </a:math> ). There was no difference in the mean ablation volume to lesion volume ratio between the two. The mean PSA percentage change from baseline to 6-month is more significant in the conventional group (63.3% vs. 44.6%, <c:math xmlns:c="http://www.w3.org/1998/Math/MathML" id="M2"> <c:mi>p</c:mi> <c:mo>=</c:mo> <c:mn>0.035</c:mn> </c:math> ). No suspicious lesion was seen at 6-month mpMRI in all 20 patients. Two patients, one from each group, eventually underwent radical treatment because of the presence of clinically significant prostate cancer in the form of out-of-field recurrences during follow-up biopsy. No significant difference was observed before and after HIFU concerning uroflowmetry, SF-12 score, and EPIC-26 score. It was observed that energy used per volume was positively correlated with PSA density of the patient (r = 0.6364, <e:math xmlns:e="http://www.w3.org/1998/Math/MathML" id="M3"> <e:mi>p</e:mi> <e:mo>=</e:mo> <e:mn>0.014</e:mn> </e:math> ). Conclusion. In conclusion, HIFU with conventional or MRI-US fusion platform provided similar oncological and functional outcomes.

References

24