Clinical Chemistry · 2021 · 17 citations · 21 references
MedicineCardiologyInternal MedicineClinical CardiologyClinical Decision SupportInterventional CardiologyAcute Coronary SyndromesCardiac AssessmentCardiac BiomarkersCardiac Risk AssessmentCardiovascular AssessmentIschemic Heart DiseaseAcute Coronary Syndrome DetectionAcute Myocardial Infarction DiagnosisDiagnostic Performance MetricsHigh-sensitivity Troponin AssaysMyocardial Infarction Risk StratificationNon-st-elevation Myocardial InfarctionTroponin ElevationTroponin Interpretation
BACKGROUND: The European Society of Cardiology (ESC) rule-out algorithms use cutoffs optimized for exclusion of non-ST elevation myocardial infarction (NSTEMI). We investigated these and several novel algorithms for the rule-out of non-ST elevation acute coronary syndrome (NSTE-ACS) including less urgent coronary ischemia. METHOD: A total of 1504 unselected patients with suspected NSTE-ACS were included and divided into a derivation cohort (n = 988) and validation cohort (n = 516). The primary endpoint was the diagnostic performance to rule-out NSTEMI and unstable angina pectoris during index hospitalization. The secondary endpoint was combined MI, all-cause mortality (within 30 days) and urgent (24 h) revascularization. The ESC algorithms for high-sensitivity cardiac troponin T (hs-cTnT) and I (hs-cTnI) were compared to different novel low-baseline (limit of detection), low-delta (based on the assay analytical and biological variation), and 0-1-h and 0-3-h algorithms. RESULTS: The prevalence of NSTE-ACS was 24.8%, 60.0% had noncardiac chest pain, and 15.2% other diseases. The 0-1/0-3-h algorithms had superior clinical sensitivity for the primary endpoint compared to the ESC algorithm (validation cohort); hs-cTnT: 95% vs 63%, and hs-cTnI: 87% vs 64%, respectively. Regarding the secondary endpoint, the algorithms had similar clinical sensitivity (100% vs 94%-96%) but lower clinical specificity (41%-19%) compared to the ESC algorithms (77%-74%). The rule-out rates decreased by a factor of 2-4. CONCLUSION: Low concentration/low-delta troponin algorithms improve the clinical sensitivity for a combined endpoint of NSTEMI and unstable angina pectoris, with the cost of a substantial reduction in total rule-out rate. There was no clear benefit compared to ESC for diagnosing high-risk events.
21
Optimal Medical Therapy with or without PCI for Stable Coronary Disease
William E. Boden, Robert A. O’Rourke, Koon Teo et al. · New England Journal of Medicine · 2007 · 4.7K citations · Full text
Third universal definition of myocardial infarction
Kristian Thygesen, Burkert Pieske, Steven P. Schulman et al. · European Heart Journal · 2012 · 3.1K citations
How to use high-sensitivity cardiac troponins in acute cardiac care
K. Thygesen, Johannes Mair, Evangelos Giannitsis et al. · European Heart Journal · 2012 · 777 citations · Full text