PubMed · 1982 · 19 citations · 0 references
MedicineClinical SciencesPhysiologyPulmonary Function TestingPulmonologyVentilationChronic Obstructive Pulmonary DiseaseObstructive Lung DiseasePulmonary MechanicsPulmonary PhysiologyRespiratory DiseaseRespiratory PhysiologyBreathing Pattern EffectsChronic Obstructive Pulmonary Disease PathophysiologyChronic Obstructive Pulmonary Disease VentilationHypercapnia PhysiologyImpaired Gas ExchangeRespiratory Gas ExchangeRespiratory ResponseVentilatory Response To Hypercapnia
The results of lung function tests (total and functional residual capacities, residual volume/total lung capacity ratio, forced expiratory volume in one second) breathing patterns and arterial PO2 and PCO2 were studied in 651 ambulatory male patients with chronic obstructive pulmonary disease, functionally and clinically stable. Function tests were only loosely correlated with gas tensions: abnormalities in mechanics and in gas exchange are not necessarily related. In patients matched for the degree of obstruction, the breathing pattern depended upon both PaO2 and PaCO2. Isolated hypoxemia was accompanied by increased respiratory frequency without any variation in tidal volume: this suggests that the chemoreceptive systems still responded to changes in PaO2. Isolated hypercapnia was accompanied by a decrease in tidal volume and an increase in respiratory frequency. Consequently, the dead space/tidal volume ratio increased, leading to a drop in alveolar ventilation and to CO2 retention.