PubMed · 2010 · 218 citations · 77 references
Open access
DentistryRadiologyTemporomandibular DisordersPediatric Temporomandibular DisordersTemporomandibular Disorder Clinical ExaminationTemporomandibular Disorder EpidemiologyImaging AssessmentTemporomandibular Joint ImagingTemporomandibular Joint RadiographyClinical Diagnostic ValidityComprehensive Medical HistoryCriterion ValidityCriterion Validity AssessmentReference StandardsTemporomandibular Joint Imaging InterpretationValidation Study DesignValidity Of Diagnostic Criteria
The RDC/TMD Validation Project aimed to assess the diagnostic validity of the RDC/TMD examination protocol and to provide an overview of its methodology, descriptive statistics, and participant data. The study developed reliable reference standards for Axis I diagnoses using consensus of two independent examiners, and assessed intersite and intrasite reliability of criterion examiners and radiologists annually. Diagnostic agreement between criterion examiners and reference standards was excellent (kappa ≥ 0.81) except for osteoarthrosis (k = 0.53), with intrasite agreement ≥ 0.95 and intersite radiologist reliability ranging from good to excellent (k = 0.71–0.84), confirming the RDC/TMD’s reliability and validity.
The purpose of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Validation Project was to assess the diagnostic validity of this examination protocol. The aim of this article is to provide an overview of the project's methodology, descriptive statistics, and data for the study participant sample. This article also details the development of reliable methods to establish the reference standards for assessing criterion validity of the Axis I RDC/TMD diagnoses.The Axis I reference standards were based on the consensus of two criterion examiners independently performing a comprehensive history, clinical examination, and evaluation of imaging. Intersite reliability was assessed annually for criterion examiners and radiologists. Criterion examination reliability was also assessed within study sites.Study participant demographics were comparable to those of participants in previous studies using the RDC/TMD. Diagnostic agreement of the criterion examiners with each other and with the consensus-based reference standards was excellent with all kappas > or = 0.81, except for osteoarthrosis (moderate agreement, k = 0.53). Intrasite criterion examiner agreement with reference standards was excellent (k > or = 0.95). Intersite reliability of the radiologists for detecting computed tomography-disclosed osteoarthrosis and magnetic resonance imaging-disclosed disc displacement was good to excellent (k = 0.71 and 0.84, respectively).The Validation Project study population was appropriate for assessing the reliability and validity of the RDC/TMD Axis I and II. The reference standards used to assess the validity of Axis I TMD were based on reliable and clinically credible methods.
77
Lenore Sawyer Radloff · Applied Psychological Measurement · 1977 · 53.3K citations · Full text
The Pittsburgh sleep quality index: A new instrument for psychiatric practice and research
Daniel J. Buysse, Charles F. Reynolds, T. H. Monk et al. · Psychiatry Research · 1989 · 34.7K citations
Medicine, Psychiatry, Psychology +16
A Global Measure of Perceived Stress
Sheldon Cohen, Robin Mermelstein · Journal of Health and Social Behavior · 1983 · 32.4K citations
The McGill Pain Questionnaire: Major properties and scoring methods
Ronald Melzack · Pain · 1975 · 6.9K citations
Nursing, Psychology, Pain Management +15