EngineeringNuclear EngineeringRadiation DetectionRadiation DosimetryRadiation MeasurementBackground Radiation MeasurementContaminant AnalysisDrinking Water SafetyRadiochemical AnalysisScintillation DetectorsWater QualityDrinking Water MonitoringLiquid Scintillation CountingRadonRadon Background MeasurementRadon MeasurementRadon MonitoringRadon TracingWater Contaminant Assessment
It has been confirmed that, in the measurement of radon-in-water using liquid scintillation counting, the direct method is preferred to the extraction method, since the former is simple technique. With a counting time of 60 minutes, the minimum detectable radon concentration by the extraction method and the direct method were found to be 0.03 Bq/kg and 1 Bq/kg, respectively. The minimum detectable radon concentration of 1 Bq/kg attained by the direct method is sufficient to check the radon concentration in drinking water below the Maximum Contaminant Level (11.1 Bq/L) proposed by the U. S. Environmental Protection Agency. The total net counting rates were estimated by the zero level extrapolating method. The optimized window values of the 3 efficiency tracing points were 50 keV - ∞, 75 keV - ∞ and 100 keV - ∞. The efficiency tracing method has been proved useful with LSCs that are currently available in Japan.