PubMed · 2007 · 88 citations · 24 references
MedicineOrthopedic SurgerySurgeryMusculoskeletal InfectionOrthopedicsWound HealingFracture FixationFracture ManagementFracture-related InfectionInternal FixationOrthopedic InfectionDeep Space InfectionFracturesLocking Plate InfectionMinimally Invasive Plate OsteosynthesisPlate Fixation InfectionTibia FracturesTibial Shaft Fractures
We report a series of 42 patients reviewed at a mean of 19.6 months after treatment of distal tibial and pilon fractures using the AO distal tibia locking plate with a minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. Mean time to union was 22.4 weeks. All fractures united with acceptable alignment and angulation. Two cases of superficial infection were noted, with one case of deep infection. Mean SF36 score was 85 and mean AOFAS score was 90 at a mean of 19 months follow-up. We report satisfactory outcomes with the use of the AO distal tibia locking plate in treatment of unstable distal tibial fractures. Eighty-nine percent of the patients felt that they were back to their pre injury status and 95% back to their previous employment.
24
Stanley R. Mandel, Paul F. Jaques, Matthew A. Mauro et al. · Annals of Surgery · 1987 · 417 citations · Full text
Fractures of the tibial plafond.
Dror Ovadia, R K Beals · Journal of Bone and Joint Surgery · 1986 · 366 citations