PubMed · 2009 · 82 citations · 46 references
Open access
DentistryImplant DentistryProsthodonticsCraniofacial ProstheticsMechanical Properties Of Dental MaterialsProstheticsImplant DesignImplant Prosthesis DesignMaxillofacial Prosthesis DesignMaxillofacial ProstheticsBiomechanical SimulationBiomechanical Testing Of ImplantsBiomechanics Of Implant-supported OverdenturesCantilever MechanicsCompressive StrengthCortical Bone StructureImplant ProstheticsImplant Stress Distribution
PURPOSE: The purpose of the study was to evaluate, using finite element analysis, the stress patterns induced in cortical bone by three distinct implant-supported prosthetic designs. MATERIALS AND METHODS: The first two models consisted of a prosthesis supported by four implants, the distal two of which were tilted, with different cantilever lengths (5 mm and 15 mm). The third design consisted of a prosthesis supported by five conventionally placed implants and a 15-mm cantilever. RESULTS: In the tilted model with 5-mm cantilever and in the nontilted model, the maximum value of compressive stress (-18 MPa) was found near the cervical area of the distal implant. Higher values for compressive stress were predicted near the cervical area of the distal implant in the tilted model with a 15-mm cantilever, as compared to the tilted model with the 5-mm cantilever. For the tilted model with the 5-mm cantilever, peak values of tensile stress were predicted near the cervical area of both the distal (1.25 MPa) and the mesial implants (2.5 MPa). For the nontilted model, the peak value was found near the cervical area of the in-between implant (5 MPa). For the tilted model with 15-mm cantilever, tensile stress values were higher than in the tilted model with 5-mm cantilever. CONCLUSIONS: No significant difference in stress patterns between the tilted 5-mm and the nontilted 15-mm configuration was predicted. The tilted configuration with a 15-mm cantilever was found to induce higher stress values than the tilted configuration with a 5-mm cantilever.
46
Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.
R Adell, U. Breine, Johan Lindström et al. · PubMed · 1977 · 2.4K citations
Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws.
R Adell, Bengt O. Eriksson, Ulf Lekholm et al. · PubMed · 1990 · 1.9K citations
Paulo Maló, Bo Rangert, Miguel de Araújo Nobre · Clinical Implant Dentistry and Related Research · 2003 · 763 citations
Biomechanical considerations in osseointegrated prostheses
Richard Skalak · Journal of Prosthetic Dentistry · 1983 · 756 citations