Ziehl-Neelsen staining: strong red on weak blue, or weak red under strong blue?

Prikshat Kumar Angra, M Becx-Bleumink, Christopher Gilpin, Moses Joloba, Kirsten Jost, KM Kam, S J Kim, Richard Lumb, Satoshi Mitarai, Andrew Ramsay,

PubMed · 2007 · 13 citations · 3 references

Concepts

Abstract

FOR ACID-FAST BACILLI (AFB) staining, the International Union against Tuberculosis and Lung Disease (The Union) and the World Health Organization (WHO) guidelines recommend 0.3% basic fuchsin for the primary staining solution and 0.3% aqueous methylene blue for counterstaining.1,2 The recommended Ziehl-Neelsen (ZN) technique uses carbol fuchsin for 5 min (3‐5 min in the WHO guidelines), with repeated heating and 1 min counterstaining. Both guidelines advise correcting the amount of dye with purity below 88%. If these guidelines are followed strictly, acceptable results may be achieved. However, there is insufficient margin for error and we regularly see inadequately stained smears: pink or pale red AFB stain, thin and incompletely stained AFB, barely visible bacilli or a high proportion of smears with low quantifications. In contrast, among countries using hot carbol fuchsin at 1%, robust, strongly stained red bacilli that are easily visible are generally seen, even though the overall performance level of their AFB microscopy network may not be better. The quality of the basic fuchsin procured, the reagent preparation and its quality control, as well as storage conditions, may lead to poor solutions being used. Particularly in large, busy laboratories, this will often be exacerbated by sloppy execution (thick smears, insufficient heating and/or staining time), superficial reading of smears or a poor quality microscope, with numerous false negatives as the final result. Furthermore, dye purity is rarely specified, making corrections impossible. When a 0.3% solution of methylene blue is used for over 1 min, excessive counterstaining occurs, especially for thick smears, resulting in a very dark blue colour which may hide large numbers of AFB. In contrast, use of 0.1% methylene blue for 1 min, as used routinely in some countries, produces a desired light blue background without a tendency to overstain. The original ZN method used basic fuchsin at about 1%.3 The 0.3% modification was introduced in the USA, and was subsequently incorporated into Union guidelines. No evaluation of equivalence for this change could be traced.4 Elaborate experiments published around the same time found that 1% basic fuchsin with maintained heating for 15 min was optimal (concentrations below 1% were not even considered), and that picric acid was superior to methylene blue as a counterstain.5 Dissmann showed that methylene blue was the cause of inferior ZN performance, hiding AFB in thick smears.6 A research centre reported equal sensitivity but reduced specificity for 1% versus 0.3% basic fuchsin.7 However, the sample included follow-up specimens, suggesting that the ‘lower specificity’ was rather the result of better staining of non-viable bacilli. A large multi-centre field study by a high-quality network confirmed that specificity was preserved and more positives were detected by 1% basic fuchsin, and that a significantly higher sensitivity was reached when the two study arms were combined.8 In conclusion, both field experience and already performed studies strongly suggest that a revision of Union and WHO guidelines for ZN staining is necessary, paying particular attention to the following points:

References

3