Exploratory Tests of Transpiration Cooling on a Porous 8 Degree Cone at M = 2.05 Using Nitrogen Gas, Helium Gas, and Water as the Coolants

Leo T Chauvin, Howard S Carter

University of North Texas Digital Library (University of North Texas) · 1955 · 12 citations · 0 references

Full text

Open access

Concepts

Abstract

Report presenting an investigation of the effectiveness of transpiration cooling on an 8 degree total-angle conical body with a porous skin for various coolant mass flow rates of nitrogen gas, helium gas, and distilled water.