Results of a 50% Waste Loading Vitrification Test Using the Cold Crucible Melter for Savannah River Site Waste

A. P. Kobelev, S. V. Stefanovsky, O.A. Knyazev, T. N. Lashchenova, A.G. Ptashkin, Polkanov, E.W. Holtzscheiter, J. C. Marra

OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 2006 · 14 citations · 0 references

Concepts

Abstract

The Cold Crucible Induction Melter (CCIM) is a promising alternative compared to the Joule heated ceramic melter (JHCM) reference technology for vitrification of high level radioactive waste (HLW). Successful tests with 45 wt.% waste loading in the glass facilitated the transition to the third task of the work with waste loading increased to 50 wt.%. The third test was performed using the Radon full-scale vitrification plant equipped with a new cylindrical cold crucible with an inner diameter of 418 mm. Average glass pour rate (average amount of glass poured per 1 hour of run) and specific glass pour rate (average pour rate per melter surface area) reached 16.2 kg/h and {approx}118.2 kg/(m{sup 2}h), respectively. Neither formation of sulfate/chloride salts ('yellow phase') nor melt foaming were observed. Occurrence of a spinel-type phase in the glass didn't reduce chemical durability of the glass. Product Consistency Testing (PCT) demonstrated that leaching of lithium, boron, sodium and silicon from glass samples produced in the CCIM were 15 to 30 times lower than the Environmental Assessment (EA) glass used for waste form repository acceptance. (authors)