68Ga-P15-041, A Novel Bone Imaging Agent for Diagnosis of Bone Metastases

Rui Guo, Xiangxi Meng, Fei Wang, Jiangyuan Yu, Qing Xie, Wei Zhao, Lin Zhu, Hank F. Kung, Zhi Yang, Nan Li

Frontiers in Oncology · 2021 · 14 citations · 32 references

DOIFull text

Open access

Concepts

Abstract

Objectives 68 Ga-P15-041 ( 68 Ga-HBED-CC-BP) is a novel bone-seeking PET radiotracer, which can be readily prepared by using a simple kit formulation and an in-house 68 Ga/ 68 Ge generator. The aim of this study is to assess the potential human application of 68 Ga-P15-041 for clinical PET/CT imaging and to compare its efficacy to detect bone metastases of different cancers with 99 mTc-MDP whole-body bone scintigraphy (WBBS). Methods Initial kinetic study using Patlak analysis and parametric maps were performed in five histopathologically proven cancer patients (three males, two females) using 68 Ga-P15-041 PET/CT scan only. Another group of 51 histopathologically proven cancer patients (22 males, 29 females) underwent both 99 mTc-MDP WBBS and 68 Ga-P15-041 PET/CT scans within a week, sequentially. Using either pathology examination or follow-up CT or MRI scans as the gold standard, the diagnostic efficacy and receiver operating characteristic curve (ROC) of the two methods in identifying bone metastases were compared (p <0.05, statistically significant). Results Fifty-one patients were imaged, and 174 bone metastatic sites were identified. 68 Ga-P15-041 PET/CT and 99 mTc-MDP WBBS detected 162 and 81 metastases, respectively. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 68 Ga-P15-041 PET/CT and 99 mTc-MDP WBBS were 93.1% vs 81.8%, 89.8% vs 90.7%, 77.5% vs 69.2%, 97.2% vs 93.4% and 90.7% vs 88.4%, respectively. Our results showed that the mean of SUVmax was significantly higher in metastases than that in benign lesions, 15.1 ± 6.9 vs . 5.6 ± 1.3 (P <0.001). Using SUVmax = 7.6 as the cut-off value by PET/CT, it was possible to predict the occurrence of metastases (AUC = 0.976; P <0.001; 95% CI: 0.946–0.999). However, it was impossible to distinguish osteoblastic bone metastases from osteolytic bone lesions. Parametric maps based on Patlak analysis provided excellent images and highly valuable quantitative information. Conclusions 68 Ga-P15-041 PET/CT, offering a rapid bone scan and high contrast images in minutes, is superior to the current method of choice in detecting bone metastases. It is reasonable to suggest that 68 Ga-P15-041 PET/CT could become a valuable routine nuclear medicine procedure in providing excellent images for detecting bone metastases in cancer patients. 68 Ga-P15-041 could become a valuable addition expanding the collection of 68 Ga-based routine nuclear medicine procedures where 18 F fluoride is not currently available.

References

32