Natural SciencesChemistryMaterials ScienceBiosensorsElectrochemistrySensorsElectroanalytical ChemistryElectrochemical BiosensorsElectrochemical DetectionElectrochemical SensorsElectrode MaterialsEnzymatic BiosensorsElectrochemical SensingGlucose SensingGlucose SensorsMetal-organic Framework SensorsMetal-organic FrameworksOxidationResponse TimeSelectivity
A non-enzymatic electrochemical sensor for glucose detection is executed by using a conductive metal–organic framework (MOF) Cu-MOF, which is built from the 2,3,6,7,10,11-hexahydroxytriphenylene (HHTP) ligand and copper acetate by hydrothermal reaction. The Cu-MOF demonstrates superior electrocatalytic activity for glucose oxidation under alkaline pH conditions. As an excellent non-enzymatic sensor, the Cu-MOF grown on Cu foam (Cu-MOF/CF) displays an ultra-low detection limit of 0.076 μM through a wide concentration range (0.001–0.95 mM) and a strong sensitivity of 30,030 mA μM −1 cm −2 . Overall, the Cu-MOF/CF exhibits a low detection limit, high selectivity, excellent stability, fast response time, and good practical application feasibility for glucose detection and can promote the development of MOF materials in the field of electrochemical sensors.
49
New Porous Crystals of Extended Metal-Catecholates
Mohamad Hmadeh, Zheng Lu, Zheng Liu et al. · Chemistry of Materials · 2012 · 931 citations
Proceedings of the Society for Analytical Chemistry · 1970 · 603 citations