NeuroImage · 2021 · 36 citations · 126 references
MedicineBioengineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingFunctional NeuroimagingImagingMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMedical ImagingEcho Planar ImagingHigh-field Magnetic Resonance ImagingIterative Image ReconstructionIterative ReconstructionMagnetic Field InhomogeneityMagnetic Resonance Imaging AcquisitionSingle-shot ImagingUltra-high-field Magnetic Resonance Imaging
Spiral fMRI has been put forward as a viable alternative to rectilinear echo-planar imaging, in particular due to its enhanced average k-space speed and thus high acquisition efficiency. This renders spirals attractive for contemporary fMRI applications that require high spatiotemporal resolution, such as laminar or columnar fMRI. However, in practice, spiral fMRI is typically hampered by its reduced robustness and ensuing blurring artifacts, which arise from imperfections in both static and dynamic magnetic fields. Recently, these limitations have been overcome by the concerted application of an expanded signal model that accounts for such field imperfections, and its inversion by iterative image reconstruction. In the challenging ultra-high field environment of 7 Tesla, where field inhomogeneity effects are aggravated, both multi-shot and single-shot 2D spiral imaging at sub-millimeter resolution was demonstrated with high depiction quality and anatomical congruency. In this work, we further these advances towards a time series application of spiral readouts, namely, single-shot spiral BOLD fMRI at 0.8 mm in-plane resolution. We demonstrate that high-resolution spiral fMRI at 7 T is not only feasible, but delivers both excellent image quality, BOLD sensitivity, and spatial specificity of the activation maps, with little artifactual blurring. Furthermore, we show the versatility of the approach with a combined in/out spiral readout at a more typical resolution (1.5 mm), where the high acquisition efficiency allows to acquire two images per shot for improved sensitivity by echo combination.
126
The FAIR Guiding Principles for scientific data management and stewardship
Mark D. Wilkinson, Michel Dumontier, IJsbrand Jan Aalbersberg et al. · Scientific Data · 2016 · 17.8K citations · Full text
John Ashburner, Karl Friston · NeuroImage · 2005 · 7.5K citations
Julia: A Fresh Approach to Numerical Computing
Jeff Bezanson, Alan Edelman, Stefan Karpinski et al. · SIAM Review · 2017 · 6.3K citations
SENSE: Sensitivity encoding for fast MRI
Klaas P. Pruessmann, Markus Weiger, Markus B. Scheidegger et al. · Magnetic Resonance in Medicine · 1999 · 6.1K citations