Efficient and Compact Dual-band Wireless Power Transfer System through Biological Tissues Using Dual-Reference DGS Resonators

Jiang Xin, Fairus Tahar, Takashi Miyamoto, Adel Barakat, Kuniaki Yoshitomi, Ramesh K. Pokharel

2021 · 15 citations · 7 references

Concepts

Abstract

This paper presents a novel design for a compact dual-band wireless power transfer (WPT) system through biological tissues using dual-reference defected ground structure (DGS) resonators. Overlapping is used to minimize the size to be suitable for biomedical applications. The proposed DGS resonator exhibits bandstop characteristics at two different frequencies depending on the excitation reference-plane. Then, two coupled sets of the proposed dual-reference DGS, in a back-to-back configuration, achieves a dual-band WPT system. The sizes of the receiver and transmitter are 15 mm × 15 mm and 18 mm × 18 mm, respectively. The measured efficiencies are 60.3% at 381 MHz and 54.3% at 750 MHz when the receiver is embedded in chicken breast within a depth of 10 mm, while the overall WPT distance of 11 mm

References

7