Min. Eng. (Littleton, Colo.); (United States) · 1988 · 15 citations · 0 references
EngineeringBiotechnologyMining EngineeringCombustionMine PlanningMine SafetyHeat ControlMine Fire ControlMine Fire PreventionCarbon Monoxide DetectionCombustion Control In MinesCombustion Of Coal In MinesContinuous MonitoringGas MonitoringInfrared ThermographySpontaneous Combustion PreventionThermography
An early warning system is the most effective tool for preventing and controlling spontaneous combustion. A combination of infrared thermography and continuous monitoring of carbon monoxide provides adequate warning before it is too late to gain control over such heatings. Use of sealants to prevent air leakage should be practiced more extensively, particularly in mines prone to spontaneous heating. Inertization techniques have proven valuable in controlling the onset of spontaneous heating in gob areas and in coal storage silos. All coal mines should consider suitable emergency planning, including a supply of inert gas, so that once a heating is detected, it can be controlled without delay. Another feasible method for controlling spontaneous combustion involves biotechnology. Methane oxidizing microorganisms are brought into contact with the coal to oxidize the methane to nonflammable products. 13 refs., 3 figs., 1 tab.