Investigative Radiology · 2021 · 15 citations · 18 references
MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyImage InterpretationBreast Cancer ImagingBreast Density AssessmentBreast ImagingBreast Lesion CharacterizationComputed TomographyRadiographic AssessmentBenign Breast Disease EvaluationBi-rads ClassificationBreast Imaging FindingsBreast Lesion DiagnosisBreast Mass AssessmentComparative Diagnostic PerformanceDiagnostic Performance MetricsFibroglandular Tissue Quantification
OBJECTIVES: This study aimed to evaluate the diagnostic performance of the maximum intensity projection (MIP) reformations of breast computed tomography (B-CT) images as a stand-alone method for the detection and characterization of breast imaging findings. MATERIALS AND METHODS: A total of 160 women undergoing B-CT between August 2018 and December 2020 were retrospectively included; 80 patients with known breast imaging findings were matched with 80 patients without imaging findings according to age and amount of fibroglandular tissue (FGT). A total of 71 benign and 9 malignant lesions were included. Images were evaluated using 15-mm MIP in 3 planes by 2 radiologists with experience in B-CT. The presence of lesions and FGT were evaluated, using the BI-RADS classification. Interreader agreement and descriptive statistics were calculated. RESULTS: The interreader agreement of the 2 readers for finding a lesion (benign or malignant) was 0.86 and for rating according to BI-RADS classification was 0.82. One of 9 cancers (11.1%) was missed by both readers due to dense breast tissue. BI-RADS 1 was correctly applied to 73 of 80 patients (91.3%) by reader 1 and to 74 of 80 patients (92.5%) by reader 2 without recognizable lesions. BI-RADS 2 or higher with a lesion in at least one of the breasts was correctly applied in 69 of 80 patients (86.3%) by both readers. For finding a malignant lesion, sensitivity was 88.9% (95% confidence interval [CI], 51.75%-99.72%) for both readers, and specificity was 99.3% (95% CI, 96.4%-100%) for reader 1 and 100% (95% CI, 97.20%-100.00%) for reader 2. CONCLUSIONS: Evaluation of B-CT images using the MIP reformations may help to reduce the reading time with high diagnostic performance and confidence.
18
Interrater reliability: the kappa statistic
Marry L. McHugh · Biochemia Medica · 2012 · 18.6K citations · Full text
European cancer mortality predictions for the year 2019 with focus on breast cancer
Matteo Malvezzi, Greta Carioli, Paola Bertuccio et al. · Annals of Oncology · 2019 · 241 citations · Full text
Medicine, Oncology, Breast Oncology +15
Sandy Napel, Geoffrey D. Rubin, R. Brooke Jeffrey · Journal of Computer Assisted Tomography · 1993 · 190 citations