International Journal of Hydrogen Energy · 2021 · 87 citations · 42 references
EngineeringEnergy EfficiencyEnergy ConversionHigher CapexRefrigerationChemical EngineeringElectrolyzer CellShared BalanceAdvanced Energy TechnologyWater TreatmentElectrolyzed WaterHealth SciencesElectrical EngineeringEnergy StorageIndividual BopEnergy EngineeringElectrochemistryEnergy ManagementEnvironmental EngineeringDesign ConsiderationsWater ElectrolysisElectrolysis Of Water
The motivation of this work is to propose a shared balance of plant (BoP) and power supply (PS) design for industrial scale alkaline electrolyzer plant that has reduced CAPEX with a minimum loss in OPEX for variable load operation. Three important aspects are: a) flowsheet - either shared or individual BoP and PS per stack, b) variable or constant lye flowrate per stack and c) sizing of cooling duty in the lye circulation loop. Steady-state optimization shows that individual BoP per stack (with higher CAPEX) is optimal when the plant is expected to operate at high capacity. For shared BoP and PS, the hydrogen production is higher by 8–12% when operated with variable lye flowrate compared to fixed lye flowrate. Our results further suggest that lye cooling duty should be designed based on the cooling requirements of the degraded electrolyzer stacks at end of life.
42
Renewable Power-to-Gas: A technological and economic review
Manuel Götz, Jonathan Lefebvre, Friedemann Mörs et al. · Renewable Energy · 2015 · 2.4K citations · Full text