Physiological Measurement · 2021 · 16 citations · 61 references
EngineeringCardiologyOtolaryngologyHearing AssessmentPhysiological Systems ModelingUltrasonographyBlood Pressure Signal AnalysisHemodynamicsVital SignsVital Signs AssessmentVital Signs RecordingBlood PressureBlood Pressure EstimationFeature Extraction From Blood Pressure SignalsNoninvasive Blood Pressure MeasurementPhotoplethysmogram Blood Pressure EstimationPhotoplethysmogram Signal ProcessingPhotoplethysmography-based Blood Pressure EstimationSystolic Blood Pressure Estimation
Abstract Objective . In this study, we aimed to estimate blood pressure (BP) from in-ear photoplethysmography (PPG). This novel implementation provided an unobtrusive and steady way of recording PPG, whereas previous PPG measurements were mostly performed at the wrist, finger, or earlobe. Methods . The time between forward and reflected PPG waves was very short at the ear site. To minimize errors introduced by feature extraction, a multi-Gaussian decomposition of in-ear PPG was performed. Both hand-crafted and whole-based features were extracted and the best combination of features was selected using a backward-search wrapper method and evaluated by the Akaike information criteria. Hemodynamic parameters such as compliance and inertance were estimated from a four-element Windkessel (WK4) model, which was used to pre-classify PPG signals and generate different BP estimation algorithms. Calibration was done by using previous measurements from the same class. To validate this novel approach, 53 subjects were recruited for a one-month follow-up study, and 17 subjects were recruited for a two-month follow-up study. Calibrated systolic BP estimation accuracy was significantly improved with inertance-based pre-classification, while diastolic BP showed less improvement. Results . With proper feature selection, pre-classification and calibration, we have achieved a mean absolute error of 5.35 mmHg for SBP estimation, compared to 6.16 mmHg if no pre-classification was carried out. The performance did not deteriorate in two months, showing a decent BP trend-tracking ability. Conclusion . The study demonstrated the feasibility of in-ear PPG to reliably measure BP, which represents an important technological advancement in terms of unobtrusiveness and steadiness.
61
L. F. Shampine, Mark W. Reichelt · SIAM Journal on Scientific Computing · 1997 · 3.6K citations · Full text
Natural Sciences, Computer Science, Differential Equations +9
Wearable Photoplethysmographic Sensors—Past and Present
T. Tamura, Yuka Maeda, Masaki Sekine et al. · Electronics · 2014 · 877 citations · Full text
Engineering, Biomedical Engineering, Electrical Engineering +17
Noninvasive Assessment of the Digital Volume Pulse
Sandrine Millasseau, Franck G. Guigui, Ronan P. Kelly et al. · Hypertension · 2000 · 291 citations · Full text
Engineering, Cardiology, Physiology +15