Korean Journal of Radiology · 2021 · 42 citations · 26 references
MedicineRadiologySurgeryBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyComputed TomographyImage QualityImage Quality AssessmentMedical ImagingMusculoskeletal ImagingSpine ImagingImage DenoisingImage Noise ReductionImage SharpeningImage Sharpness AssessmentLumbar Spine ImagingRadiation Dose ReductionSharpeningSignal-to-noise Ratio
The purpose of this study was to assess whether a deep learning (DL) algorithm could enable simultaneous noise reduction and edge sharpening in low-dose lumbar spine CT. Materials and Methods: This retrospective study included 52 patients (26 male and 26 female; median age, 60.5 years) who had undergone CT-guided lumbar bone biopsy between October 2015 and April 2020. Initial 100-mAs survey images and 50-mAs intraprocedural images were reconstructed by filtered back projection. Denoising was performed using a vendor-agnostic DL model (ClariCT.AI TM , ClariPI) for the 50-mAS images, and the 50-mAs, denoised 50-mAs, and 100-mAs CT images were compared. Noise, signal-to-noise ratio (SNR), and edge rise distance (ERD) for image sharpness were measured. The data were summarized as the mean standard deviation for these parameters. Two musculoskeletal radiologists assessed the visibility of the normal anatomical structures. Results: Noise was lower in the denoised 50-mAs images (36.38 7.03 Hounsfield unit [HU]) than the 50-mAs (93.33 25.36 HU) and 100-mAs (63.33 16.09 HU) images (p < 0.001). The SNRs for the images in descending order were as follows: denoised 50-mAs (1.46 0.54), 100-mAs (0.99 0.34), and 50-mAs (0.58 0.18) images (p < 0.001). The denoised 50-mAs images had better edge sharpness than the 100-mAs images at the vertebral body (ERD; 0.94 0.2 mm vs. 1.05 0.24 mm, p = 0.036) and the psoas (ERD; 0.42 0.09 mm vs. 0.50 0.12 mm, p = 0.002). The denoised 50-mAs images significantly improved the visualization of the normal anatomical structures (p < 0.001). Conclusion: DL-based reconstruction may enable simultaneous noise reduction and improvement in image quality with the preservation of edge sharpness on low-dose lumbar spine CT. Investigations on further radiation dose reduction and the clinical applicability of this technique are warranted.
26
Interrater reliability: the kappa statistic
Marry L. McHugh · Biochemia Medica · 2012 · 18.6K citations · Full text
Interrater reliability: the kappa statistic.
Mary L. McHugh · PubMed · 2012 · 9.2K citations · Full text
Deep learning–based image restoration algorithm for coronary CT angiography
Fuminari Tatsugami, Toru Higaki, Yuko Nakamura et al. · European Radiology · 2019 · 264 citations
Medicine, Cardiology, Radiology +14
How I Do It: Managing Radiation Dose in CT
William W. Mayo-Smith, Amy K. Hara, Mahadevappa Mahesh et al. · Radiology · 2014 · 196 citations