Indian Journal of Ophthalmology · 2021 · 11 citations · 10 references
MedicineOphthalmologySurgeryAnterior SegmentOphthalmic SurgeryTransplant SurgeryCorneal DisordersCorneal PathologyCorneal TransplantationCorneal Wound HealingCorneal Endothelial AssessmentCorneal Endothelial Cell DensityCorneal Endothelial Cell LossCorneal Thickness AssessmentCorneal Transplant EvaluationDonor Cornea PreservationDonor Cornea QualityPhysical Quality Attributes
Purpose: To compare the physical and microbiological characteristics of McCarey-Kaufman (MK), Cornisol, and Optisol-GS media and evaluate the outcomes of keratoplasty performed using corneas stored in these three media. Methods: The study involved 60 donor corneas which were distributed in 3 groups: MK, Cornisol, and Optisol-GS. Corneas in these groups were further analyzed based on the type of keratoplasty performed (full thickness versus endothelial keratoplasty). At baseline, the endothelial cell density and death to preservation time of donor corneas were recorded. Following keratoplasty, patients were evaluated on day 1, at 1 month, 3 months, and 6 months follow-up. Outcomes were assessed in terms of corrected distance visual acuity (CDVA), endothelial cell density, percentage endothelial cell loss, and corneal thickness. The storage media were also assessed for their physical quality and their microbiological characteristics. Results: Physical characteristics of all three media were found to be within normal limits. Mean CDVA was comparable among the 3 groups at 6-month follow-up. The absolute endothelial cell count values were significantly lower for corneas stored in MK medium (1873.7 ± 261.1 cells/mm 2 ) compared to the Cornisol (2085.0 ± 230.3 cells/mm 2 ) and Optisol-GS media [(2180.3 ± 217.2 cells/mm 2 ) ( P = <0.001)]. Corneas stored in Optisol-GS medium were significantly thinner at 1-month follow-up with no significant difference at 6 months ( P = 0.66). Conclusion: Optisol-GS and Cornisol media were found to preserve endothelial cell density better and stabilize corneal thickness earlier as compared to the MK medium. However, the functional outcomes were comparable among the three groups.
10
Optisol Corneal Storage Medium
Richard L. Lindstrom, Herbert E. Kaufman, Debra L. Skelnik et al. · American Journal of Ophthalmology · 1992 · 165 citations
Donor Age and Factors Related to Endothelial Cell Loss 10 Years after Penetrating Keratoplasty
Jonathan H. Lass, Beth Ann Benetz, Robin L. Gal et al. · Ophthalmology · 2013 · 124 citations · Full text
Medicine, Ophthalmology, Surgery +15
Comparison of Chen Medium and Optisol-GS for Human Corneal Preservation at 4°C
William M. Bourne, Leif R. Nelson, Leo J. Maguire et al. · Cornea · 2001 · 49 citations
Medicine, Ophthalmology, Surgery +15