Fracture of the inferior pole of the patella: tension band wiring versus transosseous reattachment

33

Citations

21

References

2021

Year

Abstract

For treating inferior pole patellar fracture, both TWB and TOR were effective and had a low clinical failure rate. In 60% of patients undergoing TBW fixation, however, additional surgery was required to remove the implants. Patella baja occurred immediately following TOR, but the patellar height was similar to that in the TBW group after 3 months. Surgeons should be aware of the high risk of postoperative radiological loss of reduction, especially when the fracture displacement is more than 30 mm.