1977 · 24 citations · 0 references
EngineeringChemical EngineeringMechanical EngineeringAir ConditioningHeat TransferTransport PhenomenaDew PointFog FormationBoiler OperationBoilersConvective Heat TransferConvective Mass TransferDew Point CalculationDew Point MeasurementMass Flow TheorySpecific Heat Capacity
The theory of convective mass transfer is used to calculate the rate of deposition of sulphuric acid on cooled surfaces in boiler flues. The mass deposited per unit area per second is ah/c (p/sub Ag/ - p/sub As/) where h is the coefficient of convective heat transfer, c is the specific heat of the gas and a is a factor having a value of about 1.9; p/sub Ag/ and p/sub As/ are the partial pressures of sulphuric acid in the bulk of the gas and in saturated gas at the temperature of the surface. Values of p/sub A/ are tabulated against dew-point temperature and water vapour content. The theory explains how fog formation in the gas reduces the rate of acid deposition within a certain band of temperature between the acid dew-point and the water dew-point. The rate of deposition on a probe is shown to depend on the local mass flow as well as on the acid content. By contrast the dew-point depends only on the acid content. The sensitivity of the dew-point meter to changes in acid content is not very high but it is adequate for the control of combustion. A continuously recording dew-point meter is being successfully used on industrial boilers.