Annals of Translational Medicine · 2021 · 10 citations · 30 references
MedicineCardiologyBiomedical Signal ProcessingElectrophysiologyResuscitationCardiac Signal ProcessingCardiopulmonary ResuscitationCardiovascular MonitoringElectrocardiogram AnalysisElectrocardiographyResuscitation MonitoringAmplitude Spectrum AnalysisArtifact SuppressionElectrocardiographic Artifact AnalysisOut-of-hospital Cardiac ArrestSignal Artifact RecognitionSignal Quality AssessmentSignal Quality MonitoringVentricular Fibrillation Detection
Background: Amplitude spectrum area (AMSA) calculated from ventricular fibrillation (VF) can be used to monitor the effectiveness of chest compression (CC) and optimize the timing of defibrillation. However, reliable AMSA can only be obtained during CC pause because of artifacts. In this study, we sought to develop a method for estimating AMSA during cardiopulmonary resuscitation (CPR) using only the electrocardiogram (ECG) waveform.Methods: Intervals of 8 seconds ECG and CC-related references, including 4 seconds during CC and an adjacent 4 seconds without CC, were collected before 1,008 defibrillation shocks from 512 out-of-hospital cardiac arrest patients. Signal quality was analyzed based on the irregularity of autocorrelation of VF. If signal quality index (SQI) was high, AMSA would be calculated from the original signal. Otherwise, CC-related artifacts would be constructed and suppressed using the least mean square filter from VF before calculation of AMSA. The algorithm was optimized using 480 training shocks and evaluated using 528 independent testing shocks.Results: Overall, CC resulted in lower SQI [0.15 (0.04–0.61) with CC vs. 0.75 (0.61–0.83) without CC, P<0.01] and higher AMSA [11.2 (7.7–16.2) with CC vs. 7.2 (4.9–10.6) mVHz without CC, P<0.01] values. The predictive accuracy (49.2% vs. 66.5%, P<0.01) and area under the receiver operating characteristic curve (AUC) (0.647 vs. 0.734, P<0.01) were significantly decreased during CC. Using the proposed method, the estimated AMSA was 7.1 (5.0–15.2) mVHz, the predictive accuracy was 67.0% and the AUC was 0.713, which were all comparable with those calculated without CC.Conclusions: Using the signal quality-based artifact suppression method, AMSA can be reliably estimated and continuously monitored during CPR.
30
Executive Summary: Heart Disease and Stroke Statistics—2014 Update
Alan S. Go, Dariush Mozaffarian, Véronique L. Roger et al. · Circulation · 2014 · 1.4K citations · Full text
Medicine, Cardiology, Health Policy +12
Sheldon Cheskes, Robert H. Schmicker, Jim Christenson et al. · Circulation · 2011 · 380 citations · Full text
Predicting the success of defibrillation by electrocardiographic analysis
Heitor P. Póvoas, Max Harry Weil, Wanchun Tang et al. · Resuscitation · 2002 · 137 citations