Circulation · 1992 · 34 citations · 0 references
MedicineCardiologyClinical CardiologyPulmonologyUltrasonographyCardiac UltrasonographyCardiac UltrasoundCirculatory AnatomyCirculatory PhysiologyEchocardiographic Hemodynamic AssessmentHemodynamicsCurvatureInterventricular SeptumPressure Gradient MeasurementPulmonary Arterial PressurePulmonary HemodynamicsTransmitral Pressure GradientTransvalvular Pressure GradientVentricular Septum
BACKGROUNDAt end diastole, the position and shape of the ventricular septum depend on the transseptal pressure gradient. It is not clear, however, how the septal radius of curvature changes in response to the gradual change in transseptal pressure gradient during progressive pulmonary arterial constriction (PAC) and aortic constriction (AC).METHODS AND RESULTSIn 11 anesthetized open-chest dogs, the septal radius of curvature was measured from the short-axis two-dimensional echocardiogram, and the transseptal pressure gradient (left ventricular [LV] pressure minus right ventricular [RV] pressure) was calculated from ventricular pressures measured with micromanometers. Seven dogs were studied with both PAC and AC (group 1) and four dogs only with PAC, which was initiated before and after volume loading (group 2). The transseptal pressure gradient decreased during PAC. As the transseptal pressure gradient decreased, the septum shifted continuously leftward with decreases in the LV septum-free wall diameter a...