Journal of Personalized Medicine · 2021 · 27 citations · 9 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBone GraftingJoint Replacement SurgeryOrthopedicsAseptic LooseningComplications Of ArthroplastyHip ArthroplastyRevision ArthroplastyRevision Joint ReplacementAcetabular Component FixationAcetabular Deficiency ReconstructionAcetabular LooseningComplications Of Revision ArthroplastyDislocation After Hip ArthroplastyHip ReconstructionPaprosky ClassificationRevision Arthroplasty Reconstruction
Purpose: Patient-specific, flanged acetabular components are used for the treatment of Paprosky type III defects during revision total hip arthroplasty (THA). This monocentric retrospective cohort study analyzes the outcome of patients treated with custom made monoflanged acetabular components (CMACs) with intra- and extramedullary iliac fixation. Methods: 14 patients were included who underwent revision THA with CMACs for the treatment of Paprosky type III defects. Mechanism of THA failure was infection in 4 and aseptic loosening in 10 patients. Seven patients underwent no previous revision, the other seven patients underwent three or more previous revisions. Results: At a mean follow-up of 35.4 months (14–94), the revision rate of the implant was 28.3%. Additionally, one perioperative dislocation and one superficial wound infection occurred. At one year postoperatively, we found a significant improvement of the Western Ontario and McMaster Universities Arthritis Index (WOMAC) score (p = 0.015). Postoperative radiographic analysis revealed good hip joint reconstruction with a mean leg length discrepancy of 3 mm (−8–20), a mean lateralization of the horizontal hip center of rotation of 8 mm (−8–35), and a mean proximalization of the vertical hip center of rotation of 6 mm (13–26). Radiolucency lines were present in 30%. Conclusion: CMACs can be considered an option for the treatment of acetabular bone loss in revision THA. Iliac intra- and extramedullary fixation allows soft tissue-adjusted hip joint reconstruction and improves hip function. However, failure rates are high, with periprosthetic infection being the main threat to successful outcome.
9
Kevin J. Bozic, Atul F. Kamath, Kevin Ong et al. · Clinical Orthopaedics and Related Research · 2014 · 455 citations · Full text
Construct Rigidity: Keystone for Treating Pelvic Discontinuity
J. Ryan Martin, Ian J. Barrett, Rafael J. Sierra et al. · Journal of Bone and Joint Surgery · 2017 · 51 citations
Radiological determination of the anatomic hip centre from pelvic landmarks.
Markus D. Schofer, Thomas Pressel, Thomas J. Heyse et al. · PubMed · 2010 · 32 citations
Sebastian G. Walter, Thomas M. Randau, Nadine Gravius et al. · The Journal of Arthroplasty · 2019 · 28 citations