The Analyst · 2021 · 12 citations · 43 references
EngineeringBioengineeringBiomedical EngineeringBiomemsMicroelectromechanical SystemsMobile SystemsMicrofluidic BiosensorsMicrofluidic Device FabricationMicrofluidic DevicesMicrofluidic SystemsMicrofluidicsNucleic Acid ExtractionMicrofluidic Device DesignMicrofluidic Diagnostic DevicesMicrofluidic Diagnostic PlatformsMicrofluidic PlatformsMicrofluidic SensingNucleic Acid AnalysisSample Preparation MicrodevicesSmartphone-integrated Biosensors
Mobile sensing based on the integration of microfluidic devices and smartphones, so-called MS2 technology, has enabled many applications over recent years and continues to stimulate growing interest in both research communities and industries. In particular, MS2 technology has been proven to be able to be applied to molecular diagnostic analysis and can be implemented for basic research and clinical testing. However, the currently reported MS2-based nucleic acid analysis system has limited use in practical applications, because it is not integrated with quantitative PCR, multiplex PCR, and isothermal amplification functions, and lacks temperature control, image acquisition and real-time processing units with excellent performance. To provide a more universal and powerful platform, we here developed a novel MS2 device by integrating a thermocycler, a multi fluorescence detection unit, a PCR chip, an isothermal chip, and a smartphone. The MS2 device was approximately 325 mm (L) × 200 mm (W) × 200 mm (H) in volume and only 5 kg in weight, and showed an average power consumption of about 38.4 W. The entire nucleic acid amplification and analysis could be controlled through a self-made smartphone App. The maximum heating and cooling rates were 5 °C s-1 and 4 °C s-1, respectively. The entire PCR could be completed within 65 min. The temperature uniformity was less than 0.1 °C. Besides, the temperature stability over time (30 min) was within ±0.04 °C. Four optical channels were integrated (FAM, HEX, TAMRA, and ROX) on the MS2 device. In particular, the PCR-based detection sensitivity reached 1 copy per μL, and the amplification efficiency was calculated to be 106.8%. Besides, the MS2 device also was compatible with multiplex PCR and isothermal amplification. In short, the MS2 device showed performance consistent with that of traditional commercial equipment. Thus, the MS2 device provides an easy and integrated experimental platform for molecular diagnostic-related research and potential medical diagnostic applications.
43
Jasper Fuk‐Woo Chan, Cyril Chik‐Yan Yip, Kelvin Kai‐Wang To et al. · Journal of Clinical Microbiology · 2020 · 936 citations · Full text
Instrument-Free Point-of-Care Molecular Detection of Zika Virus
Jinzhao Song, Michael G. Mauk, Brent A. Hackett et al. · Analytical Chemistry · 2016 · 316 citations · Full text
A smartphone-read ultrasensitive and quantitative saliva test for COVID-19
Bo Ning, Tao Yu, Shengwei Zhang et al. · Science Advances · 2021 · 249 citations · Full text
The modern role of smartphones in analytical chemistry
Maryam Rezazadeh, Shahram Seidi, Marthe Lid et al. · TrAC Trends in Analytical Chemistry · 2019 · 237 citations