Diabetes Technology & Therapeutics · 2021 · 242 citations · 17 references
MedicineEndocrinologyInternal MedicineDiabetologyHealth AssessmentHealth Technology AssessmentBlood Glucose MonitoringContinuous Glucose MonitoringDiabetes ManagementDiabetes MellitusGlycemic ControlGlycemic MonitoringClosed-loop Insulin TherapyGlucose MonitoringGlucose Monitoring DevicesReal-world Performance EvaluationType 1 Diabetes Monitoring
Background: The t:slim X2™ insulin pump with Control-IQ ® technology from Tandem Diabetes Care is an advanced hybrid closed-loop system that was first commercialized in the United States in January 2020. Longitudinal glycemic outcomes associated with real-world use of this system have yet to be reported. Methods: A retrospective analysis of Control-IQ technology users who uploaded data to Tandem's t:connect ® web application as of February 11, 2021 was performed. Users age ≥6 years, with >2 weeks of continuous glucose monitoring (CGM) data pre- and >12 months post-Control-IQ technology initiation were included in the analysis. Results: In total 9451 users met the inclusion criteria, 83% had type 1 diabetes, and the rest had type 2 or other forms of diabetes. The mean age was 42.6 ± 20.8 years, and 52% were female. Median percent time in automation was 94.2% [interquartile range, IQR: 90.1%–96.4%] for the entire 12-month duration of observation, with no significant changes over time. Of these users, 9010 (96.8%) had ≥75% of their CGM data available, that is, sufficient data for reliable computation of CGM-based glycemic outcomes. At baseline, median percent time in range (70–180 mg/dL) was 63.6 (IQR: 49.9%–75.6%) and increased to 73.6% (IQR: 64.4%–81.8%) for the 12 months of Control-IQ technology use with no significant changes over time. Median percent time <70 mg/dL remained consistent at ∼1% (IQR: 0.5%–1.9%). Conclusion: In this real-world use analysis, Control-IQ technology retained, and to some extent exceeded, the results obtained in randomized controlled trials, showing glycemic improvements in a broad age range of people with different types of diabetes.
17
Violin Plots: A Box Plot-Density Trace Synergism
Jerry L. Hintze, Ray D. Nelson · The American Statistician · 1998 · 1.6K citations
Feasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Garry M. Steil, Kerstin Rebrin, Christine Darwin et al. · Diabetes · 2006 · 467 citations · Full text
A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes
Marc D. Breton, Lauren Kanapka, Roy W. Beck et al. · New England Journal of Medicine · 2020 · 429 citations · Full text
Medicine, Child Health, Pediatrics +17