OTA International The Open Access Journal of Orthopaedic Trauma · 2020 · 18 citations · 25 references
We found no significant difference in axial load to failure values between long and short intramedullary nail fixation in 2 unstable intertrochanteric fracture patterns in a composite femur model. Short nails exhibited greater stiffness in axial loads in the A1 pattern and torsional stiffness in the A3 pattern. This suggests short or long intramedullary nails could be appropriately employed for fixation of unstable intertrochanteric hip fracture patterns.
25
SH Bridle, A.D. Patel, M. Bircher et al. · Journal of Bone and Joint Surgery - British Volume · 1991 · 546 citations
Mechanical validation of whole bone composite femur models
Luca Cristofolini, Marco Viceconti, Angelo Cappello et al. · Journal of Biomechanics · 1996 · 495 citations