IEEE Transactions on Radiation and Plasma Medical Sciences · 2021 · 27 citations · 31 references
EngineeringComputer EngineeringElectrical EngineeringAnalog ElectronicsField-programmable Gate ArraysReconfigurable ComputingDetector TechnologyDigital InstrumentationDigital Signal ProcessingField-programmable Gate Array ArchitectureFpga ArchitectureCarry Chain DesignDetector Energy ResolutionField-programmable Gate Arrays (Fpgas)Fpga PrototypingPhotomultiplier DetectorsRadiation Energy ResolutionReadoutSilicon Photomultiplier Arrays
The aim of this study is to design and evaluate a simple free running analog–digital converter (ADC) based on the field-programmable gate array (FPGA) device to accomplish the energy and position readout of the silicon photomultiplier (SiPM) array for application as positron emission computed tomography scanners. This simple FPGA-ADC based on a carry chain time-digital converter (TDC) implemented on a Kintex-7 FPGA consists of only one off-chip resistor so it has greater advantages in improving system integration and reducing cost than commercial chips. In this article, an FPGA-ADC-based front-end electronics prototype is presented, and both the design principle and implementation considerations are discussed. Experiments were performed using an <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$8 \times 8$ </tex-math></inline-formula> (crystal size: 4 mm <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\times $ </tex-math></inline-formula> 4 mm <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\times $ </tex-math></inline-formula> 15 mm) and a 12 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\times $ </tex-math></inline-formula> 12 (crystal size: 2.65 mm <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\times $ </tex-math></inline-formula> 2.65 mm <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\times $ </tex-math></inline-formula> 15 mm) segmented LYSO crystals coupled with an <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$8 \times 8$ </tex-math></inline-formula> SiPM (J-series, from ON Semiconductor) array which is under <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">22</sup> Na point source excitation. Initial test results indicate that the energy resolution of the two detectors after correction is around 13.2% and 13.5% at 511 keV, and the profiles of the flood histograms show a clear visualization of the discrete scintillator element. All measurements were carried out at room temperature (~ 25°C), without additional cooling.
31
TOFPET ASIC for PET applications
M. Rolo, R. Bugalho, F.M. Gonçalves et al. · Journal of Instrumentation · 2013 · 124 citations · Full text
Comparison between new-generation SiPM-based and conventional PMT-based TOF-PET/CT
Kei Wagatsuma, Kenta Miwa, Muneyuki Sakata et al. · Physica Medica · 2017 · 115 citations