ACS Omega · 2021 · 162 citations · 43 references
EngineeringBioengineeringBiomedical EngineeringBiosensorsNanotechnologySensorsBiomedical SensorsBiosensors For Immune DetectionMicrofluidic BiosensorsMolecular SensorsNanomaterial-based BiosensorsNanosensorsAntigen-antibody InteractionsElectrochemical TransductionField-effect Transistor BiosensorsField-effect Transistor SensorsGrapheneGraphene SensorsGraphene-based SensorsVirus Detection Biosensors
An MXene-graphene field-effect transistor (FET) sensor for both influenza virus and 2019-nCoV sensing was developed and characterized. The developed sensor combines the high chemical sensitivity of MXene and the continuity of large-area high-quality graphene to form an ultra-sensitive virus-sensing transduction material (VSTM). Through polymer linking, we are able to utilize antibody-antigen binding to achieve electrochemical signal transduction when viruses are deposited onto the VSTM surface. The MXene-graphene VSTM was integrated into a microfluidic channel that can directly receive viruses in solution. The developed sensor was tested with various concentrations of antigens from two viruses: inactivated influenza A (H1N1) HA virus ranging from 125 to 250,000 copies/mL and a recombinant 2019-nCoV spike protein ranging from 1 fg/mL to 10 pg/mL. The average response time was about ∼50 ms, which is significantly faster than the existing real-time reverse transcription-polymerase chain reaction method (>3 h). The low limit of detection (125 copies/mL for the influenza virus and 1 fg/mL for the recombinant 2019-nCoV spike protein) has demonstrated the sensitivity of the MXene-graphene VSTM on the FET platform to virus sensing. Especially, the high signal-to-viral load ratio (∼10% change in source-drain current and gate voltage) also demonstrates the ultra-sensitivity of the developed MXene-graphene FET sensor. In addition, the specificity of the sensor was also demonstrated by depositing the inactivated influenza A (H1N1) HA virus and the recombinant 2019-nCoV spike protein onto microfluidic channels with opposite antibodies, producing signal differences that are about 10 times lower. Thus, we have successfully fabricated a relatively low-cost, ultrasensitive, fast-responding, and specific inactivated influenza A (H1N1) and 2019-nCoV sensor with the MXene-graphene VSTM.
43
Electric Field Effect in Atomically Thin Carbon Films
Kostya S. Novoselov, A. K. Geǐm, Da Jiang et al. · Science · 2004 · 66.1K citations · Full text
25th Anniversary Article: MXenes: A New Family of Two‐Dimensional Materials
Michael Naguib, Vadym N. Mochalin, Michel W. Barsoum et al. · Advanced Materials · 2013 · 6.3K citations
New insights into the structure and reduction of graphite oxide
Wei Gao, Lawrence B. Alemany, Lijie Ci et al. · Nature Chemistry · 2009 · 2.5K citations
Natural Sciences, Materials Engineering, Materials Science +5